7
EN
Torque scale and output torque
CAUTION
The torque scale is for reference. The output torque range is not guaranteed.
Make sure to measure torque.
Use the tool within the specified range.
When the torque decreases, increase the torque based on the measured value.
DLV30A Series
High T
orque
Spring
Low T
orque
Spring
Torque (Nm)
Torque (Nm)
Torque Scale
Torque Scale
DLV45A/DLV70A Series
DL
V70A
DLV45A
SP type signal specifications
WARNING
Always use the signal output within the output rating.
Use of the tool at a voltage or current value above the rating could cause the tool to fail.
Do not directly connect the relay, motor, lamp, etc. to control.
It could cause the tool to fail due to surge, etc. generated from inductive load.
CAUTION
The start signal is output even when the start switch is turned ON while the changeover switch of forward and
reverse rotation is at the neutral position.
When torque-up occurs in the reverse rotation, the torque-up signal is also output.
Output signal specification
Signal output
Open collector
Rated voltage
80 V DC or less
Rated current
Maximum 20 mA per output