Pre-Operation Checks
• Is the wiring correctly performed?
• Is the capacity of the fuse and the thermal relay appropriate?
• Is the product correctly installed?
• Is the ground connection properly done?
Trial Operation Checks
•
If the direction is wrong, refer to “ 6. Wiring.” and change the wiring.
• Connect to the machine and operate at no load.
If there is no abnormality, gradually increase the load up to full load.
Routine Operation Checks
• Refer to the details of the daily inspection and check the state of operation.
Immediately stop the operation if there is any abnormality.
Otherwise, device damage, injury, fire, an electric shock and burn may occur.
•
Switch on for 1 to 2 seconds under no load to check the rotational direction before installing to the driven
machine.
Refer to “10. Troubleshooting,” etc. for the diagnosis when an abnormality occurred and do not operate the
motor until the causes of the error are found and corrective actions are taken.
Immediately stop operation of the gearmotor if there is any abnormality. Otherwise, an electric
shock, injury and fire may occur.
Do not use the motor with load that exceeds the rating. Otherwise, injury and device damage may
occur.
Do not perform impact stop to the motor. Otherwise, this may give a negative impact to the
gearmotor and the connecting machine.
Do not remove the fan of the gearmotor without brake whose capacity is 0.4 kW or more.
If once removed, it will be impossible to install properly.
Securing it to the motor shaft will be incomplete and it may come off. If it is removed, please
contact our nearest service office.
7. Operation
DANGER
Do not operate the motor while the terminal box cover is removed.
Mount the terminal box cover to the original position after work. Otherwise, an electric shock may
occur.
Do not approach or touch rotating bodies (output shafts, etc.) while the product is running.
Otherwise, entanglement and injury may occur.
Be sure to turn off the power switch when power failure occurs.
Otherwise, sudden power recovery may cause injury and device damage.
CAUTION
Do not touch the gearmotor which may be hot when energized or for a while after the power-off.
It may result in burns.
Do not use a gearmotor with clutch and brake for lifting(elevation) application.
Drop accidents may occur when power fails.
37
Содержание GTR MID F Series
Страница 16: ... Blank page 16 ...