Precautions on Gearmotor with Brake Wiring
• The brake voltage is 90V DC for the 200V class brake and 180V DC for the 400V class brake.
The brake lead wires are blue for the 200V class brake and yellow for the 400V class brake.
•
※
200V Class Brakes (Blue lead wires) cannot be used with 400V power.
※
400V Class Brakes (Yellow lead wires) cannot be used with 200V power.
• Utilize “DC Switching” if the motor is used for lifting applications.
• Connect a surge suppressor (option) between the contacts for DC Switching connection.
Please contact your local service office for details of the surge suppressor. (Optional Accessory).
(The varistor voltage is 423V to 517V for the 200V class brake and 820V to 1000V for the 400V class brake.)
•
*The value within < > is for motor with a 400V Class Brake.
•
• Input voltage to the rectifier must be within the range as specified below. Please beware that repeated operation
beyond the range may cause malfunction.
[
200V Class
]
:
AC200V
~
230V±10%
:
AC200V
~
220V±10%
[
400V Class
]
:
AC380V
~
480V±10%
Brake Lag Time
︓
ta
Time(seconds) taken from switch off to start of braking.
(Differs from the braking time.)
Standard Type (Brake Model
:
B2, B4, J2, J4)
Water-resistant Type IP65 (Brake Model
:
V2, V4)
AC Switching (B)
Capacity
DC Switching
Capacity
DC Switching
AC Switching (A)
AC Switching (B)
0.1 kW to 0.75 kW
0.005 to 0.015
0.03 to 0.13
0.1 to 0.3
Use switches of 110V DC <220V DC> and with contact point capacity rating of 13 DC to block the inductive load
(DC coil) when using DC Switching. Please contact your local service office for further details.
0.1 kW to 0.75 kW
0.005 to 0.020
0.05 to 0.15
0.15 to 0.25
1.5 kW, 2.2 kW
0.015 to 0.030
0.15 to 0.30
Please note that in case of products(power type: K and C) where voltage of both 200V class and 400V class
are displayed on the motor nameplate, the voltage that can be used will vary depending on the brake voltage
*"Contact point rating of 13 DC" is a type of classification under JIS C 8201-5-1 (Low voltage switching device
and control device) for coil load applications.
Note that the rectifier has a diode built in, which may become unusable if a short circuit occurs due to improper
connections, etc.
0.5 to 0.6
AC Switching (A)
A200-D90-UL
A200-D90
A400-D180