47
*3 Irrespective of the settings, dynamic brakes are disabled if the free-run stop (I8) is OFF.
N: Unsaved constant
-
Initializing the constants: Constants related to initialization
Initial
value
Attribute
N
Unit
-
0
Unit
Pn401
Clearing the
alarm history
Clear the alarm history.
0: Does not clear the alarm history
1: Clear the alarm history
-
0
~
1
0
No.
Name
Details
Set range
Pn400
Initializing the
user constants
Initialize the user constants.
0: Does not initialize
1: Initialize the user constants
0
~
1
Unit
-
0
~
1
0
No.
Name
Details
Set range
Initial
value
N
-
Pn240
Selection of dynamic
brake function after
stopping
Attribute
Dynamic break constants: Constants related to dynamic break
No.
Name
Details
-
Pn403
Reserving the constant
Do not change the settings.
-
-
-
-
Select the dynamic brake function after
stopping. *3
0: Not used
1: Used (Disabled during emergency
stop)
2: Used (Enabled during emergency stop)
3: Used (Disabled during emergency stop
or forceful release of mechanical brake)
4: Used (Enabled during emergency stop
and disabled during forceful release of
mechanical brake)
-
0
~
4
0
-
Safety constants: Constants related to safety
Pn245
Selection of overload
detection method
Set the selection of overload detection
method.
0: Electronic thermal system
1: Motor current continuous detection
system
Pn402
Set range
Initial
value
Attribute
Pn246
Overload detection
interval
Set the overload detection interval of the
motor current continuous detection
system.
When the motor current is constantly
100% or more, and if it is detected more
than or equal to this constant, there is an
overload.
sec
0.01
~
10.00
10.00
Reserving the constant
Do not change the settings.
-
-
-
Содержание A-BLPQ010S2-V2
Страница 1: ...Instruction manual GTR AR Series APQ VER2 Driver...
Страница 27: ...27...
Страница 37: ...37...