34
Un007
Error history
The history of the errors occurred on the driver is displayed.
Error history records last 10 errors.
・
Following are the display details.
(1)
History No. (0 to 9 (10 errors), 0 is the latest)
(2)
(3)
Alarm information
(2) Detailed part specifications
When input is on, the corresponding LED turns on.
Display example
This example shows that the latest error is the pole sensor error, and
only I1, I3 input terminals were ON at that time.
Un008
Software version
The software version of the driver is displayed.
Display example
This example shows that the software version of the driver is 0001.
Un009
Integrated motor overload value
The internal integrated value till an electric overload alarm rings is displayed.
The motor load will reach to 80% immediately after the power supply is turned on. (Hot start)
Display example
Input terminal status (The input terminal status immediately after
alarm generation)
It easily increases with the increase in the motor load, and when it reaches to 100%, the electric
overload alarm rings.
This example shows that the integrated value of electric overload will
reach to 80% of alarm generation.
(1) (2)
(3)
I1
I2
I3
I8
I4
I6
I7
I5