Nilfisk-ALTO 03KLU Скачать руководство пользователя страница 17

15

  10.0  Model designation   

EN

The Nilfi sk-ALTO 03K-series of cold water cleaners 
is produced in several models. The model des ig na-
 tion is printed on the model plate, e.g. Nilfi sk-ALTO 
2603KLU. This plate provides the following details.

  1. Model designation
  2.  Nilfi sk-ALTO order no.
  3. Nozzle
  4. Pump pressure
  5.  Max. pressure
  6.  Water capacity
  7. Max. temperature
  8.  Air fl ow
  9. Approval
 10.  Serial no./production week and -year
 

  11.0  Technical data 

EN

Model 

 

2603KLU

Cleaning power adjustable max. 

kW/hp 

2.6/3.5

Pump pressure max. 

bar/psi 

120/1740

Nozzle pressure, adjustable min./max. 

bar/psi 

4/104-58/1510

Water capacity 

I/h / lmpG/h  

950/209

 

USG/h 

251

Max. pressure of inlet water 

bar/psi 

15/217

Self-priming, max. suction height 

m/ft 

5/16

Max. temp

. of inlet water 

°C/°F 

40/104

Oil capacity of oil pump 

l/lmpG/USG 

1/0.22/0.26

High pressure hose, length 

m/ft 

10/32.8

Nozzle size 

 

0640

Dimensions:  

length 

mm/inch 

1000/39.4

 

width 

mm/inch 

545/21.5

 

height  

mm/inch 

825/32.5

Weight complete 

kg/lb 

70/154

Motor 

type 

GAST-8AM

Air consumption  

m3/h-ft3/min. 

290-170

Inlet pressure 

bar/psi 

7/100

Sound pressure level (LpA) measured in accordance with ISO 11202 [

DISTANCE 1M

] [

FULL LOAD

]: 80 dB(A)

We reserve the right to amend the specifi cations.

2603KLU

P
Pmax
Q
Tmax

bar/MPa
bar/MPa
l/ min.
°C

6170000

120/12
120/12

XXXX 

IP X5

15,8
70

3

4

10

6

7

5

9

8

Luftbehov
Air Consumption
Verbrauch an Luft
Consummation d’air

290m3/h - 7bar

Made by: Nilfisk-Advance A/S, DK-2605 Broendby

Serial no./week/year

Содержание 03KLU

Страница 1: ...03KLU Instruktionsbog 1 8 User Manual 9 16 Betriebsanleitung 17 24 616 96 00 f...

Страница 2: ...Printed in Denmark Copyright 2010 Nilfisk ALTO Division of Nilfisk Advance A S...

Страница 3: ...anvisning for tilkobling af luftmotor 6 10 1 Fremstilling 6 10 2 Montering 6 10 3 Sm ring 6 10 4 Drift 6 10 5 Service 6 10 0 Modelbetegnelse 7 11 0 Driftsforstyrrelser og afhj lpning 7 12 0 Tekniske d...

Страница 4: ...gning DA 2603KLU 1 Pumpe med konsol 2 Manometer 3 Stel 4 Udbl sningsfilter 5 Sm reapparat 6 Manometer 7 Regulator 8 Filter 9 Luftmotor 10 Remstrammer 11 Vandtilgang 12 Remsk rm 13 Kilerem A21 14 Slamg...

Страница 5: ...es et eksternt vandfilter Ang ende tilslutning til luftmotor se afsnit 9 0 Med koldt vand op til 8 C kan maskinen arbejde med 5 meters h jdeforskel Pumpen og tilgangsslangen skal v re fyldt med vand i...

Страница 6: ...Stop 1 Luk for luftforsyningen 2 Luk for vandforsyningen 3 Tryk spuleh ndtagets udl ser i bund for at afla ste trykket p maskinen 4 H jtryksslangen m ikke afmonteres f r maski nen er stoppet 6 0 Frost...

Страница 7: ...m Filtret kan udtages n r lynkoblingen er skruet af 7 4 Koblinger For at modvirke ut theder og del ggelse af lynkoblinger p slanger maskine og dyser r er det af og til n dvendigt at disse reng res og...

Страница 8: ...kan variere afh ngig af i hvilken position skovlhjulene stopper i forhold til luftindtagnings bningen For at opn den nskede kraft og for at bevare trykket kan hastigheden og drejningsmomentet regulere...

Страница 9: ...20 Dysetryk v h jtryk bar 115 Vandm ngde Qmax I h 950 Maks tryk p dir tilgangsvand bar 15 Selvansug maks sugeh jde m 5 Max temperatur p tilgangsvand C 40 Olieindhold i pumpe l 1 H jtryksslange l ngde...

Страница 10: ...entages Ved sugedrift For stor sugeh jde eller for varmt L s afsnit vedr sugedrift side 2 vand Filter stoppet Filter renses se afsnit 7 3 Ved direkte vandtilgang Ikke tilstr kkelig vandforsyning Skift...

Страница 11: ...4 Operation 14 9 5 Servicing 14 10 0 Model designation 15 11 0 Diagnosis of faults and repair 15 12 0 Technical data 16 1 0 Guarantee EN Your new Nilfisk ALTO cold water high pressure cleaner is guar...

Страница 12: ...U 1 Pump with bracket 2 Manometer 3 Chassis 4 Exhaust filter 5 Lubricating device 6 Manometer 7 Regulating valve 8 Filter 9 Air motor 10 Belt tightener 11 Water inlet 12 Belt guard 13 V belt 14 Sludge...

Страница 13: ...tor see section 9 0 With cold water up to 8 C the cleaner will operate satisfactorily with up to a 5 metre diffe rence of level between cleaner and water supply The pump and the inlet hose must be con...

Страница 14: ...5 2 Stopping 1 Turn off the air supply 2 Turn off the water supply 3 Press home the trigger of the spray handle to relieve the pressure of the cleaner 4 Do not disconnect the high pressure hose until...

Страница 15: ...can be removed when the quick coupling has been unscrewed 7 4 Couplings To avoid leakages and damage to the quick couplings on hoses spray handle and spray lance it is necessary to clean and lubricat...

Страница 16: ...ss than the running torque and could vary depending on the position at which the vanes stop in relation to the air intake port The speed and torque can be regulated by using a pressure regulator or a...

Страница 17: ...h 251 Max pressure of inlet water bar psi 15 217 Self priming max suction height m ft 5 16 Max temp of inlet water C F 40 104 Oil capacity of oil pump l lmpG USG 1 0 22 0 26 High pressure hose length...

Страница 18: ...Repeat the venting procedure During self priming Suction height too high or water Read the paragraph conc self too hot priming p 6 Filter blocked Clean the filter See p 11 During direct water Insuffi...

Страница 19: ...s Luftmotors 22 9 1 Fabrikation 22 9 2 Montage 22 9 3 Schmierung 22 9 4 Betrieb 22 9 5 Service 22 10 0 Modellbezeichnung 23 11 0 Betriebsst rungen und Abhilfe 23 12 0 Technische Daten 24 1 0 Garantieb...

Страница 20: ...E 2603KLU 1 Pumpe 2 Manometer 3 Rahmen 4 Ausblasfilter 5 Schmiervorrichtung 6 Manometer 7 Regler 8 Filter 9 Hydraulikmotor 10 Riemenspanner 11 Wasseranschluss 12 Riemenschirm 13 Keilriemen A21 14 Schl...

Страница 21: ...bald das Wasser das Dosierventil durch ossen hat ist es kein Trinkwasser mehr Enth lt das Wasser Schwimmsand oder ande re Verschmutzungen soll au er des hinter der Schnellkupplung angebrachten interne...

Страница 22: ...n das Ger t in Betrieb ist 6 0 Frostsicherung DE Betrieb und Aufbewahrung bei Frost gefahr unter 0 C Das Ger t vor dem Abstellen stets vollkommen entleeren auch wenn es nur kurzzeitig abgestellt wird...

Страница 23: ...en Das Filter l t sich herausnehmen wenn die Schnellkupplung abgeschraubt worden ist 7 4 Kupplungen Um Undichtheiten und Zerst rungen der Schnell kupplungen an Schl uchen am Ger t und am Spr hrohr zu...

Страница 24: ...Um die erw nschte Kraft zu erreichen und um den Druck zu bewahren l t sich die Geschwindigkeit und das Drehmoment sich mittels eines Druck regula tors oder eines Manometerventils regulieren Es ist von...

Страница 25: ...kW 2 6 Pumpendruck bar 120 D sendruck bar 115 Wassermenge Qmax l h 950 Max Druck des direkten Zufurwassers bar 15 Selbstansaug max Saugh he m 5 Max Temperatur des Zufuhrwassers C 40 linhalt der Pumpe...

Страница 26: ...en Pr fungen nehmen unsere Vertragswerkst tten und wir selbst vor 12 0 Betriebsst rungen und Abhilfe DE Betriebsst rungen Ursache Abhilfe Ger t startet nicht Luftversorgung nicht Luftschlauch anschlie...

Страница 27: ......

Страница 28: ...s Point No 201 2nd floor above Popular Car World Western Express High way Andheri East Mumbai 400 069 Tel 91 22 321 74592 IRELAND Nilfisk ALTO Division of Nilfisk Advance Ltd Bowerbank Way Gilwilly In...