32 - FORM NO. 56043056 ConvertaMAX™ 20/26 / BA 550/650
RECOVERY SYSTEM
No
Yes
Yes
Yes
No
No
Vacuum motor will not
run (See Figure 2).
1. Try re-setting the
circuit breaker first.
2. Check continuity on
the F4 (30A) vac
motor circuit breaker
Replace the F4 (30A)
vac motor circuit breaker
Check for 24V at the
blue wire (output
terminal) on the K2 vac
motor solenoid to a Neg.
battery standoff.
Check for 24V at the
M1 vac motor
Repair or replace
the M1 vac motor
See part B vac motor
control circuit
troubleshooting guide.
Repair or replace
wiring to vac motor
TROUBLESHOOTING GUIDE ELECTRICAL
Possible Symptom
1
Vacuum motor will not run
SYMPTOM ONE
Note: Do all testing with the master key switch ON, vac switch S4 ON (squeegee lowered).
Part A: Vacuum Motor Load Circuit Troubleshooting Guide
revised 9/01