FORM NO. 56043056 ConvertaMAX™ 20/26 / BA 550/650 - 21
SCRUB BRUSH SYSTEM
TROUBLESHOOTING GUIDE ELECTRICAL
Possible Symptoms
1
Scrub brush motor(s) and solution solenoid valve do not work
2
Scrub brush motor(s) do not work
3
Scrub brush auto remove function does not work
SYMPTOM ONE
*Reference the
Description of the Battery Low Voltage Cutout Feature
in the Electrical System of this manual.
revised 9/01
Yes
No
No
Yes
Check the battery
meter, is it double
flashing?
Recharge battery
pack (the low voltage
cutout is functioning*)
Test the machine's
battery pack voltage
under load. Is it less
than 22 volts?
Voltage test reading
is above 22 volts.
See the scrub brush
system troubleshoot-
ing Symptom Two,
parts A & B.
Part A: The machine's low
voltage cutout is
functioning(*). Check to
see that the correct voltage
cutout threshold setting
has been selected (battery
type wet or gel).
Scrub brush
motor(s) & solu-
tion solenoid
valve do not work
(see Figure 1)
Part B: Also test each bat-
tery for any possible dead
cells. See Electrical Sys-
tem
Battery Maintenance
& Battery Testing
sections
and follow instructions.