Scrub System
93
Service Manual – SC1500
Service Tip:
If you’re going to reinstall the
Scrub
Deck Actuator
without readjusting the
position of the
Tube
, be careful not to
rotate the
Tube
and
Plunger
with the
Scrub Deck Actuator
out of the
machine. This can cause the
Scrub
Deck Actuator
to get out of adjustment.
8
Reinstall the scrub deck actuator by following the above steps
in reverse order.
Note:
If you’re installing a replacement scrub
deck actuator assembly, or if the scrub
deck actuator assembly has gotten out of
adjustment, you’ll need to set the tube position
as described in the
Scrub Deck Actuator
Adjustment
subsection below.
Caution:
Note that the scrub deck actuator will
automatically raise the scrub deck when you
reconnect the
Actuator Electrical Connector
and battery.
Scrub Deck Actuator Adjustment
The Scrub Deck Actuator adjustment consists of setting the
Tube
position with the retracted travel limit
switch actuated. To set the Scrub Deck Actuator position:
1
Drive the actuator motor to the up (fully retracted) position using the Service Test Mode or a jumper to
the batteries.
2
Wait until the motor stops running due to the travel limit switch opening.
Note:
Do not allow the
Tube
to
bottom out against the
Motor
Housing
.
3
Manually rotate the
Tube
toward the
Motor
Housing
until it bottoms out, then back the
Tube
out at least 1½ turn, but no more than
two full turns, in order to align the mounting
holes.
Service Tip:
Be careful not to
rotate the
Tube
prior
to installing the
Scrub
Deck Actuator
into the
machine. This can
cause the
Scrub Deck
Actuator
to get out of
adjustment.
Plunger
Tube
Scrub Deck
Actuator
Scrub Deck Actuator
Tube
Motor
Housing