12
W
A L L
- M
O U N T
I
N F R A R E D
S
E N S O R
T
roubleshooting
This manual contains instr
uctions for the WS100R only. For
specific information on the adjustment and operation of your
Niles infrared extender system, please refer to the instruction
manual included with your Niles IR main system unit (MSU140,
MSU250, MSU480 MSU440Z, IntelliControl
®
).
The bi-color blue/green LED on the front of the WS100R is a
useful troubleshooting aid. The led should light solid green
when status is detected.
The blue LED should light only when a remote command is
being received. If the LED on the WS100R “flickers”, and the
WS100R functions normally, there is no cause for concern,
some stray IR signal are being received by the WS100R but are
not being repeated.
1. Test the remote control(s) by operating the A/V equipment
directly. Replace the batteries if needed.
2. Double check the cable connections on all WS100R’s and on
the main system unit. Look for open, shorted or reversed wires.
3. Test for interference from the following sources:
• Neon or halogen lights in the room.
• Light dimmers, beginning with those closest to the
WS100R.
Observe the WS100R’s LED while performing all the tests. It is
possible to have interference from more than one source.
DS00331ACN/WS100R 1/8/04 9:47 AM Page 14