background image

4

W

A L L

- M

O U N T

I

N F R A R E D

S

E N S O R

as str

ong as remotes that use the larger AA size batteries and

have two emitters. Tests with various manufacturers’ remote
controls have shown that the operating range can vary from
a minimum of 18' to a maximum of about 30'. 

Infrared signals travel essentially line-of-sight. They will not
pass through or around solid objects. Do not rely on an IR
signal being able to “bounce” off a wall or object to the
WS100R.

The IR pickup angle of the WS100R is 30° off-axis 
(horizontal and vertical) at 18'.

Junction Boxes

The mounting depth of the WS100R is 1-1/4". When

installed, the unit extends 3/4" behind the sheetrock 
wall (assuming 1/2" sheetrock). Suitable electrical boxes 
are available from your Niles dealer or local electrical 
supply company.

DO NOT INST

ALL THE WS100R INTO ELECTRICAL

BOXES WITH 110 VOLT DEVICES.

Some states or municipalities allow devices such as the

WS100R to be installed into the same electrical box as 
110 volt devices, provided a “low-voltage partition” is used
between the devices. We do not recommend this. The cable
connected to the WS100R can act as an “antenna” for elec-
trical noise. Locating the WS100R cable too close to a light
dimmer or switch may interfere with the WS100R. 
If you must locate the WS100R near electrical devices, install
it in a separate metal electrical box, ground the box to the
electrical system ground, and route the WS100R cable 
several feet away from all electrical wiring.

TOOLS

REQUIRED

• 1/8" Standard

Slotted Screwdriver

• 1/4" Standard

Slotted Screwdriver

• Wire Stripper

DS00331ACN/WS100R  1/8/04  9:47 AM  Page 6

Содержание WS100R

Страница 1: ...WS100R B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E I N S T A L L A T I O N O P E R A T I O N G U I D E WALL MOUNT INFRARED SENSOR WS100R DS00331ACN WS100R 1 8 04 9 47 AM Page 2 ...

Страница 2: ...S100 sensors or the IntelliPad The WS100R is just one part of the three building blocks necessary to complete a Niles IR repeating system IR Main System Unit Models MSU140 MSU250 MSU480 and MSU440Z IR Sensors Keypads Models WS100 TS100 MS100 MS200 CS100 MVC100IR and the IntelliPad IR Flashers Models MF1 MF2 MF1FV MF2FV and the IRB1 An IR sensor expansion hub Model IRH610 is available to provide ad...

Страница 3: ...ll brands of A V equipment and remote controls Excellent IR receiving range you get 18 to 30 of remote control range depending upon the strength of your handheld remote 100 factory tested for pickup range and angle Small size of only 2 3 4 wide by 4 1 2 high by 1 1 4 fits in a one gang box Printed circuit board design uses surface mount tech nology SMT assuring high reliability Ideal for both home...

Страница 4: ...ent if unsure about which type of wire is best for your application WS100R Mounting Location Locating the WS100R in the center of a room usually results in the most even IR receiving coverage especially if the room is square shaped Rooms that are L shaped or long and narrow require more careful consideration With these types of rooms installing the WS100R closest to the primary loca tion of the us...

Страница 5: ...ical boxes are available from your Niles dealer or local electrical supply company DO NOT INSTALL THE WS100R INTO ELECTRICAL BOXES WITH 110 VOLT DEVICES Some states or municipalities allow devices such as the WS100R to be installed into the same electrical box as 110 volt devices provided a low voltage partition is used between the devices We do not recommend this The cable connected to the WS100R...

Страница 6: ...pical installation with an MSU250 Main System Unit 12V DC power supply supplied with the MSU250 Main System Unit plugged into an unswitched AC outlet powers the system 12V DC Power Supply Not Supplied plugged into the Switched Outlet Niles Stock FG000665 Power IR Data and Power Status Signal via category 5 cable DS00331ACN WS100R 1 8 04 9 47 AM Page 7 ...

Страница 7: ...cal Box b Category 5 cable c WS100 IR Receiver supplied d Snap on Color Insert supplied e Device Screws 2 supplied f Decora Faceplate supplied g Faceplate Screws 2 supplied b d c e e f g g a Figure 2 WS100R Parts Guide DS00331ACN WS100R 1 8 04 9 47 AM Page 8 ...

Страница 8: ...n optical feedback loop can cause erratic operation Optical feedback is similar to acoustical feedback the howling or whistling sound heard in a P A system when the microphone is too close to the speaker To avoid optical feedback 1 Re position the flasher s and or the sensor 2 Use Niles MF1or MF2 flashers and cover them with the supplied IR blockers Changing the Color of the WS100R The Decora styl...

Страница 9: ...he front of the insert Using the WS100R with the Intellipad Ci system The WS100R is fully compatible with the Niles Intellipad Ci line follow the wiring instructions in Figure 4 For specific informa tion see your Intellipad Ci manual 8 W A L L M O U N T I N F R A R E D S E N S O R 1 Green White 12V 2 Green DATA 3 Orange White GROUND 4 Blue EMPTY 5 Blue White STATUS 6 Orange EMPTY 7 Brown White EMP...

Страница 10: ...t each wire into the appropriate hole on the remov able connector plug and snap the locking tab down To help you the connector plug is keyed Insert the smooth side of the connector plug into the smooth side of the socket Don t force the scalloped side of the connector plug into the smooth side of the socket Figure 5 5 Use the shorter plate screws to fasten the Decora cover plate to the WS100R DO N...

Страница 11: ...mpletely To make the clearance nec essary for these screws you must remove the parts of the lip causing the interference There are two ways to accomplish this 1 Drill through the lip of the box at the screw points 2 Cut notches into the lip with a pair of diagonal cutters 10 W A L L M O U N T I N F R A R E D S E N S O R Figure 5 Installing the Connector DS00331ACN WS100R 1 8 04 9 47 AM Page 12 ...

Страница 12: ... command Your IR command is instantly repeated to your A V equipment Green Power Status LED When the WS100R is correctly connected as shown in Figure 1 the Green LED will stay lit as long as the preamp receiver is on When your preamp receiver is off the LED will stay off Blue Flash back LED The blue flash back LED on the WS100R visually confirms the reception of an IR command W A L L M O U N T I N...

Страница 13: ...te command is being received If the LED on the WS100R flickers and the WS100R functions normally there is no cause for concern some stray IR signal are being received by the WS100R but are not being repeated 1 Test the remote control s by operating the A V equipment directly Replace the batteries if needed 2 Double check the cable connections on all WS100R s and on the main system unit Look for op...

Страница 14: ...ine to create a feed back loop are 1 Both a sensor and a flasher are located within the same room 2 There is some low level noise or interference on your system You can eliminate optical feedback by replacing any IRB1 flooding flasher with MF1 or MF2 MicroFlashers and covering all flashers with the supplied IR blocking covers 13 W A L L M O U N T I N F R A R E D S E N S O R DS00331ACN WS100R 1 8 0...

Страница 15: ...onnections on all WS100R s Main System Unit and on the IR main system unit Consult your IR Main System Unit s manual for more detail If the WS100R does not work and the LED flickers or remains solidly lit Cover up the Sensor with a piece of cardboard your hand will actually create electromagnetic interference under some conditions Observe the IR test LED IR Test LED Off Optical Interference IR Tes...

Страница 16: ...e Which solution is best for you depends on your situation If you require further assistance contact Niles Technical Support at 1 800 289 4434 15 W A L L M O U N T I N F R A R E D S E N S O R TECH NOTE The feedback LED can be disabled if it continues to flicker or visual feedback is not desired Discrete on and off IR com mands are available on the Niles Technical support website for disabling the ...

Страница 17: ...and vertical at 18 Mounting In wall fits into most 18 cu in single gang electrical boxes at least 2 3 4 deep Decora style face plate Wiring Requirements Individual home runs of Category 5 cable Unit Dimensions 1 5 8 wide x 2 5 8 high x 1 1 4 deep Face Plate Dimensions Decora wall plate 2 3 4 wide x 4 1 2 high Contents WS100R Sensor x1 Decora Insert x1 Decora faceplate x 1 Removable connector x 1 D...

Страница 18: ...Notes 17 W A L L M O U N T I N F R A R E D S E N S O R DS00331ACN WS100R 1 8 04 9 47 AM Page 19 ...

Страница 19: ...Notes 18 W A L L M O U N T I N F R A R E D S E N S O R DS00331ACN WS100R 1 8 04 9 47 AM Page 20 ...

Страница 20: ...f Niles Audio Corporation Because we strive to improve our products All other trademarks are the property of their respective owners Niles reserves the right to change product specifications without notice The technical and other informa tion contained herein is not intended to set forth all technical and other specifications of Niles products Additional information can be obtained on line at www ...

Отзывы: