background image

Mounting Location

The IRH610 is specifically designed to conveniently fit
into a structured wiring cabinet with snap-in
“Christmas Tree” plugs or it can also be wall mounted
in an unobtrusive location.

Installation

1. Run all necessary wiring to the IRH610. Label the

wires for future reference.

2. Secure the IRH610 in a suitable location. 

• In a structured-wiring cabinet, use the conven-

ient snap-in “Christmas Tree” plugs (supplied) to
mount it in the cabinet frame. 

• On a wall or other flat surface, remove the snap-

in plugs, insert drywall screws (not supplied)
through the resulting holes, and secure the
screws to the mounting surface. TAKE CARE
NOT TO OVERTIGHTEN THE SCREWS, WHICH
COULD DAMAGE THE HOUSING.

3. Locate the connector plugs

(and remove them if they
are plugged in). 

4. Strip 1/4" of insulation from

the end of each wire.

5. Use a small flathead screw-

driver or your thumbnail to
raise the locking tabs,
exposing the holes on the
removable connector plug.

6. Insert each wire into the

appropriate hole on the
removable connector plug, and snap the locking 
tab down. 

NOTE:

To help you, the connector plug is keyed.

Insert the smooth side of the connector plug into
the smooth side of the socket. Don’t force the
scalloped side of the connector plug into the
smooth side of the socket. 

I

N

F

R

A

R

E

D

S

E

N

S

O

R

E

X

P

A

N

S

I

O

N

H

U

B

3

Figure 2

DS00351ACN_IRH610.qxp  3/8/04  10:51 AM  Page 5

Содержание Infrared Sensor Expansion Hub IRH610

Страница 1: ...S TA L L AT I O N O P E R AT I O N G U I D E B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E IRH610 IRH610 INFRARED SENSOR EXPANSION HUB DS00351ACN_IRH610 qxp 3 8 04 10 51 AM Pag...

Страница 2: ...stem with multiple sensors connected directly to the main sys tem requires a large number of connecting wires This creates an unsightly and often inconvenient installation and increases the potential...

Страница 3: ...d commercial installations UL rated to comply with all local building codes 2 years parts and labor warranty Installation Considerations Type of cable The IRH610 connects to a Niles main system unit v...

Страница 4: ...the screws to the mounting surface TAKE CARE NOT TO OVERTIGHTEN THE SCREWS WHICH COULD DAMAGE THE HOUSING 3 Locate the connector plugs and remove them if they are plugged in 4 Strip 1 4 of insulation...

Страница 5: ...N HUB INPUT 1 INPUT 4 INPUT 5 INPUT 6 INPUT 2 INPUT 3 12VDC Power supply not supplied plugged into an outlet IRH610 Expansion Hub MSU250 Main System Unit Cable runs over 500 not recommended Infrared S...

Страница 6: ...lug at the upper right is the output to the main system unit The other connector plugs are the inputs each leading from a specific infrared sensor See Figure 3 For an operational overview of your infr...

Страница 7: ...drywall screws not supplied Wiring Requirements Individual home runs of category 5 cable from each infrared sensor and a single run of category 5 cable to the Main System Unit Unit Dimensions 6 7 8 w...

Страница 8: ...cts or components thereof are manufactured under one or more U S Patents foreign equivalents and or pending patents see product for details Because we constantly strive to improve our products Niles r...