Introduction

The IRH610 is an infrared sensor expansion hub that mounts in a structured-
wiring cabinet or on a wall. It connects between the output of an infrared 
sensor and a Niles main system unit.

Niles IR repeating systems are made up of three building blocks:

• IR Main System Unit—Models MSU140, MSU250, MSU480 and MSU440Z.

• IR Sensors/Keypads—Models WS100, TS100, MS100, MS200, CS100,

MVC100IR and the IntelliPad

®

.

• IR Flashers—Models MF1, MF1VF, MF2, MF2VF and the IRB1.

An IR repeater system with multiple sensors connected directly to the main sys-
tem requires a large number of connecting wires, This creates an unsightly and
often inconvenient installation and increases the potential for connection errors.

The Niles IRH610 eliminates such problems. Simply run a single category 
5 cable from the main system unit to the expansion hub, and then connect
each of the IR sensors to the distribution hub.

TABLE OF CONTENTS

Introduction

1

Features and 
Benefits

2

Installation 
Considerations

2

Installation

3

Specifications

6

Contents

6

I

N

F

R

A

R

E

D

S

E

N

S

O

R

E

X

P

A

N

S

I

O

N

H

U

B

IRH610

Infrared Sensor
Expansion Hub

DS00351ACN_IRH610.qxp  3/8/04  10:51 AM  Page 3

Содержание Infrared Sensor Expansion Hub IRH610

Страница 1: ...S TA L L AT I O N O P E R AT I O N G U I D E B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E IRH610 IRH610 INFRARED SENSOR EXPANSION HUB DS00351ACN_IRH610 qxp 3 8 04 10 51 AM Pag...

Страница 2: ...stem with multiple sensors connected directly to the main sys tem requires a large number of connecting wires This creates an unsightly and often inconvenient installation and increases the potential...

Страница 3: ...d commercial installations UL rated to comply with all local building codes 2 years parts and labor warranty Installation Considerations Type of cable The IRH610 connects to a Niles main system unit v...

Страница 4: ...the screws to the mounting surface TAKE CARE NOT TO OVERTIGHTEN THE SCREWS WHICH COULD DAMAGE THE HOUSING 3 Locate the connector plugs and remove them if they are plugged in 4 Strip 1 4 of insulation...

Страница 5: ...N HUB INPUT 1 INPUT 4 INPUT 5 INPUT 6 INPUT 2 INPUT 3 12VDC Power supply not supplied plugged into an outlet IRH610 Expansion Hub MSU250 Main System Unit Cable runs over 500 not recommended Infrared S...

Страница 6: ...lug at the upper right is the output to the main system unit The other connector plugs are the inputs each leading from a specific infrared sensor See Figure 3 For an operational overview of your infr...

Страница 7: ...drywall screws not supplied Wiring Requirements Individual home runs of category 5 cable from each infrared sensor and a single run of category 5 cable to the Main System Unit Unit Dimensions 6 7 8 w...

Страница 8: ...cts or components thereof are manufactured under one or more U S Patents foreign equivalents and or pending patents see product for details Because we constantly strive to improve our products Niles r...

Отзывы: