Features and Benefits

The IRH610 offers a number of improvements over
other infrared expansion hubs: 

• Rustproof, weather-resistant housing of high-

impact, injection-molded plastic.

• Removable connector blocks for convenient wire

connections. 

• Small size and compact footprint, designed specifi-

cally to fit into a standard structured-wiring cabinet.

• Snap-in “Christmas tree” plugs (supplied) for quick

and easy installation in a structured-wiring cabinet.

• Also suitable for wall-mounting.

• Ideal for home and commercial installations.

• UL-rated to comply with all local building codes.

• 2 years parts and labor warranty.

Installation Considerations

Type of cable

The IRH610 connects to a Niles main system unit via
a single run of category 5 cable.

I

N

F

R

A

R

E

D

S

E

N

S

O

R

E

X

P

A

N

S

I

O

N

H

U

B

Infrared Sensor

Inputs

Infrared Sensor

Inputs

Output

to MSU

Snap-in "Christmas tree" plugs

Power

input

OUTPUT TO MSU

POWER

STATUS

+12V DC

IRH610

IR EXPANSION HUB

INPUT 1

INPUT 4

INPUT 5

INPUT 6

INPUT 2

INPUT 3

2

Figure 1

When running infrared cable be sure to avoid
locating it near AC wiring. This will avoid potential
interference over long distances.

“TECH TIP”

DS00351ACN_IRH610.qxp  3/8/04  10:51 AM  Page 4

Содержание Infrared Sensor Expansion Hub IRH610

Страница 1: ...S TA L L AT I O N O P E R AT I O N G U I D E B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E IRH610 IRH610 INFRARED SENSOR EXPANSION HUB DS00351ACN_IRH610 qxp 3 8 04 10 51 AM Pag...

Страница 2: ...stem with multiple sensors connected directly to the main sys tem requires a large number of connecting wires This creates an unsightly and often inconvenient installation and increases the potential...

Страница 3: ...d commercial installations UL rated to comply with all local building codes 2 years parts and labor warranty Installation Considerations Type of cable The IRH610 connects to a Niles main system unit v...

Страница 4: ...the screws to the mounting surface TAKE CARE NOT TO OVERTIGHTEN THE SCREWS WHICH COULD DAMAGE THE HOUSING 3 Locate the connector plugs and remove them if they are plugged in 4 Strip 1 4 of insulation...

Страница 5: ...N HUB INPUT 1 INPUT 4 INPUT 5 INPUT 6 INPUT 2 INPUT 3 12VDC Power supply not supplied plugged into an outlet IRH610 Expansion Hub MSU250 Main System Unit Cable runs over 500 not recommended Infrared S...

Страница 6: ...lug at the upper right is the output to the main system unit The other connector plugs are the inputs each leading from a specific infrared sensor See Figure 3 For an operational overview of your infr...

Страница 7: ...drywall screws not supplied Wiring Requirements Individual home runs of category 5 cable from each infrared sensor and a single run of category 5 cable to the Main System Unit Unit Dimensions 6 7 8 w...

Страница 8: ...cts or components thereof are manufactured under one or more U S Patents foreign equivalents and or pending patents see product for details Because we constantly strive to improve our products Niles r...

Отзывы: