![Nikon eclipse Ci-L Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/nikon/eclipse-ci-l/eclipse-ci-l_instruction-manual_1691821070.webp)
Chapter 3
Assembly
58
Chapter 3
Assembly
2
Assembly for Bright-field Microscopy
[Tool for assembly: hex driver]
1
Checking the input voltage
Check the input voltage indicated on the back of the
microscope. Use the microscope only if the indicated
input voltage matches the power supply voltage for the
area in which the microscope will be used.
WARNING
If the indicated voltage and the supplied voltage
differ, do not attempt to use the microscope. Contact
your nearest Nikon representative for advice.
DSC
MODEL ECLIPSE Ci-S
NIKON C
ORPORA
TION
TOKYO, JAPAN
100–240V~
0.9A
50/60Hz
MADE IN
CHINA
This dev
ice complies
with Par
t 15 of th
e FCC
Rules. Operation is subject
to the fo
llowing tw
o
conditions:
(1) this
device may not c
ause har
mful in
terference,
and (2)
this de
vice must accept any
interference
received
, includi
ng interfer
ence that m
ay cau
se
undesire
d oper
ation.
This Cl
ass A di
gital ap
parat
us compl
ies with
Canadian I
CES-003.
Cet appareil num
érique de la c
lasse A est
confirme à la
norme N
MB-003 du Canada.
9 4 0 001
4N75
INSPECTION
EQUIPMEN
T
70
60
50
40
3
0
20
1
0
0
90
80
Checking the input voltage
2
Attaching the stage
(1) Turn the coarse focus knob to remove the
cushioning material from the substage section.
(2) Turn the coarse focus knob until the elevating
section is brought to the lowermost position.
(3) Place the stage on the substage and fix into place
with the stage clamp screw.
CLAMP
T
O
RQ
UE
ND4
ND8
OUT
IN
ND4
ND8
OUT
IN
Attaching the stage
Using the filter cassette holder
Insert the filter cassette holder on the field lens of
the microscope after the stage has been raised up
to the upper limit.
CLAMP
T
O
RQ
UE
ND4
ND8
OUT
IN
Attaching a filter cassette holder
Exclusivity of the filter cassette holder
and the spacer for the nosepiece
The filter cassette holder cannot be used
simultaneously with the spacer for the nosepiece.
Input voltage
label
Stage clamp screw
Filter cassette holder
Содержание eclipse Ci-L
Страница 1: ...Upright Microscope Instruction Manual M568 E 11 8 NF 1 1 2 M568EN01 ...
Страница 2: ......
Страница 44: ...Chapter 1 Microscopy Procedures 32 Chapter 1 5 Microscopy Procedures Epi fluorescence Microscopy ...
Страница 86: ...Chapter 4 Troubleshooting 74 Chapter 4 Troubleshooting ...
Страница 90: ...Chapter 5 Maintenance and Storage 78 Chapter 5 Maintenance and Storage ...
Страница 94: ...Chapter 6 Specifications and Safety Standards 82 Chapter 6 Specifications and Safety Standards ...