JAA80551-R.3757.A
- 60・AF-S DX 8-05/3.5-5.6G ED VR -
AF-S DX 18-105 ED VR
Oscilloscope
Constant-voltage power supply
(Set voltage: 6V)
(+)
(-)
【
System configuration
】
★�
New Tool
To RS232C
terminal
AF-S DX 18-105 ED VR
Inspection & adjustment software
(
★
J18454
)
AF-I communication box
(J15306-1)
AF-I communication adapter
(J15307)
PC:
As long as PC is IBM PC/AT compatible,
any CPU type is available.
If the RS232C terminal of PC is a 9-pin type,
connect it by using the 25-pin/9-pin conversion
connector. This connector is NOT supplied as RJ,
so use commercial products on the market.
※
For this connection,
removing the rear cover ring
is necessary.
INC