JAA80551-R.3757.A
- 0・AF-S DX 8-05/3.5-5.6G ED VR -
・
Click "Calculating FFD adjustment values" on main menu.
・
Input the focus position which were measured by the horizontal-type collimator at 18mm, 50mm, and
105mm.
・
Looking through the eyepiece of horizontal-type collimator, rotate the mirror micromotion-control handle to
adjust focus, then measure focus position at 18mm (WIDE-end), 50mm, 105mm (TELE-end).
The focus position to be measured is the numeric number of boundary line at the moment when the color of
cross lines change from green to orange.
If the measured focused position does not meet the standard, take the following step and make the
adjustment.
Focal length (f)
Standard (mm)
18mm
From 0 to +0.07
50mm
From -0.25 to +0.10
105mm
From -1.10 to +0.30
Eyepiece lens
Mirror micromotion-control handle
INC