JAA80551-R.3757.A
- 0・AF-S DX 8-05/3.5-5.6G ED VR -
・
Mount the bayonet mount unit (B30).
・
Position the bayonet mount unit (B30) toward the direction of the arrow, and tighten the three screws (#99)
in numeric order from
①
to
③
.
#99×3
①
②
③
Grease:I-40
・
Tighten the two screws (#105) in numeric order from
①
to
②
.
Contact pin section
#105×2
①
②
・
Adjust the aperture lever by referring to "Aperture lever adjustment" of "Adjustment" on Page
Adjust the aperture lever by referring to "Aperture lever adjustment" of "Adjustment" on Page
A38.
Caution: Be careful NOT to pinch the GND lead wire (#1020) accidentally.
#1020
・
Inspect the AF contact position by referring to "Inspection of AF-contact pin position" of
"Adjustment" on Page A36.
B30
Lever
< Lever mounting position >
Lever mounting position >
>
INC