EN
52
10-845
10.1. Starting the programming
Authorization via IR remote control
With each push on the key, the device sounds a short key confirmation tone.
Enter master code
The yellow LED is off.
*Master code #
(FI= 6-digit serial number of the 10-845)
0
9
Programming possible
A confirmation signal sounds. LED lights up yellow during 3 sec. After, the
yellow LED flashes.
Wrong entry,
master code unknown
If you press #, a negative confirmation tone sounds. The yellow LED flashes
rapidly during 3 sec. and then switches off.
You can enter the wrong code three times. After, the code entering function
will be blocked for 2 minutes. You can no longer enter a code. The yellow LED
is on during 2 min and then switches off. Start again.
No code entered
If after 2 min. no command has been entered, the device will automatically
terminate the programming mode. The LED switches off.
10.2. Setting the operating mode
Start the programming
If not already done.
Enter the operating mode
*0 # operating mode #
(FI=0)
= 0 EFH mode
= 1 basic mode or
= 2 comfort mode
= 3 comfort-simplex mode
0
Operating mode is set
A confirmation signal sounds. LED lights up yellow during 3 sec. After, the
yellow LED flashes.
Invalid value
If you press #, a negative confirmation tone sounds. The yellow LED flashes
rapidly during 3 sec. and then flashes again.
10.3. Setting serial number of internal units
Start the programming
If not already done.
Enter serial number
*1 # SN 1 # SN 2 #
up to 32 pairs of numbers can be programmed*
always SN 2 = 0 if only SN 1 must be programmed
1
Set serial number
A positive confirmation signal sounds. LED lights up yellow during 3 sec. After,
the yellow LED flashes again.
On the SD card, a folder is made on which a log is saved.
Set more serial numbers
Repeat the aforementioned steps.
invalid value
already 32 SNs saved
SN 1 is already programmed
If you press #, a negative confirmation tone sounds. The yellow LED flashes
rapidly during 3 sec. and then flashes again.
* For the programming of the screen memory, it doesn’t matter whether the serial numbers are all programmed on one bell push button of the external unit, or
that the internal video unit was assigned to other internal video units via a parallel connection.
10.4. Deleting serial number of the internal unit
Start the programming
If not already done.
Enter serial number
*3 # SN 1 #
Log with SN 1 is deleted. Up to 32 pairs of numbers can be programmed.
Always enter SN 2 = 0 if only SN 1 must be pro-grammed.
3