EN
34
10-363
Set ExtU address
Input:
4
ExtU address
BP address = 0 to 63
(FI = 0)
Record options
Input:
5
option
value
Solely option 4:
Launch programming (Switch programming
mode of the installation on and off again)
Option:
Value:
0 Send light switch protocol
0 = no, 1 = yes
(FI = 1)
1 Accept door opening protocols
0 = no, 1 = yes
(FI = 1)
2 Restricted
(FI = 0)
3 Key confirmation tone
0 = OFF, 1 = ON
(FI = 1)
4 Switch on programming mode on power supply
and control unit, then start programming
0 = no, 1 = yes
(FI = 1)
5 Switch operating mode
0 = code lock module,
1 = keypad module
(FI = 0)
Relay switching time
Input:
8
value
Value = switching time adjustable in steps of 128 ms, 0- … 250
0 = deactivated
(FI = 24; for approx. 3 sec.)
Activate
programming lock
Input:
10
master code
Master code = max 8 digits
PLEASE NOTE !
the lock cannot be undone manually, only by professionals.
Change master code
Input:
98
old master code
new master code
new master code
Master code = max 8 digits
PLEASE NOTE !
for safety reasons the preset master code must be changed when put into service!
Load factory settings
Input:
99
master code
master code
Master code = max 8 digits
PLEASE NOTE !
set access codes are deleted
10.5. Switch off programming mode
Leave programming mode
Invoer:
9
11. USE
11.1. Open door (operating mode code lock)
Start mode
Enter access code
Enter access code.
Confirm with
.