33
EN
10-363
10.3. Start the programming
Action
Description
Only during programming, record
options,
option 4:
Switch programming mode of the
installation on and off again
(FI = 0)
On the power supply and control unit:
• press RUN/PROG key briefly, LED flashes.
• press RUN/PROG key briefly, LED is on.
On the 10-363:
Two-tone LED flashes green during 2 min.
G
activate device‘s programming mode
Enter master code
(Start programming within
2 min
.!)
Input:
Mastercode
.
(FI = serial number of the code lock module)
Correct code
During 3 sec. a positive confirmation tone sounds (one long beep), LED flashes
green (2 min).
The device can now be programmed.
G
Wrong code, master code unknown
If you press
a negative confirmation tone sounds (three beeps). You have only
3 opportunities to enter the wrong code, otherwise the code entering function will
be blocked during 2 min.
Start again.
No code entered
If after 2 min. no command has been entered, the device will automatically
terminate the programming mode. The LED will also switch off.
10.4. Programming
Determine / change access cod
First access code
second access code
etc.
Input:
0
memory location number 1
access code
access code
Invoer:
0
memory location number 2
access code
access code
Memory location number = 1 to 10
Access code = max. 8 digits (1 to 8 digits)
When changed, the old code is overwritten by the new one.
Activate / deactivate relay for code
Input:
1
memory location number
R
R – relay function
Memory location number = 1 to 10
(FI = 1 for MlNo 1 to 10)
R =
1 ON
0 OFF (relay without function)
Send protocol when determining the
code input
Input:
2
memory location number
P
P – protocolkeuze
Memory location number = 1 to 10
(FI = 0 for MlNo 1 to 10)
P =
0 (door opening protocol with own ExtU address)
1 (Control function 1 with own serial number)
2, 3, 4, 5 Free protocols
6 (MlNo with own serial number)
7 (Don’t send protocol)
Delete dataset
(for a certain
memory location)
Input:
memory location number
Memory location number = 1 to 10