EN
32
10-363
1
st
access code / parameter
(on memory location number 1)
sends door opening protocol with ExtU ad-dress, relay
switches
1
nd-
20
th
access code
(on memory location number 2 to 20)
not assigned
2
nd
-20
th
access code / parameter
(on memory location number 2 to 20)
sends door opening protocol with ExtU address, relay
switches, dataset inactive
Time-out entered code
10 sec.
Blocking time after third time wrong code
2 min.
Time-out programming mode
2 min.
Other factory settings: see programming manual function group with display module.
9.2. Configuration options
Manually
Service Unit
10-870
Niko Configuration SW
ExtU address
x
-
x
Relay switch time
x
-
x
Programming lock (ON/OFF)
x
-
x
Switch relay contact with bus door opening protocol
x
-
x
Always first switch on programming mode on power supply and control unit (ON/OFF)
x
-
x
Key confirmation tone (ON/OFF)
x
-
x
Send light switch protocol (ON/OFF)
x
-
x
Access code 1 to 10 and parameters
x *
-
x**
Load factory settings
x
-
x
* up to 10 codes
** up to 20 codes
10. PROGRAMMING
10.1. Important instructions
• When entered correctly, a positive confirmation tone sounds (
).
If the input of a command series
is interrupted during 10 seconds, the entire series is cancelled. A negative confirmation tone sounds
(
).
• Unconfirmed entered values expire after 10 sec.
• If a command series is incompatible with the requested syntax or if too many parameters are entered, the entire command series is cancelled and a
negative confirmation tone sounds.
• With each push on the key, the module sounds a short key confirmation tone (
).
• Confirm by pushing
, cancel by pushing
• The factory settings of the 10 code memory locations are shown below in brackets e.g. (FI = 0).
10.2. Legend LED display modes:
flashes every 2 sec.
flashes
ON
OFF
Green
G
G
G
Red
R