31
EN
10-363
7. CONNECTION OF THE MODULE
Wiring diagram code lock module 10-363, stand-alone mode
1
2
3
4
5
6
7
8
230 V
>6Ω
0
9
10-801
a b P
a b P
NO COM NC
10-363
10-801
1
3
14 15 16 17
24 23
25
Door opener is not included.
8. INITIAL ACTIVATION
8.1. Error detection and indication
When pressing a key (once and only in code lock mode), a visual and acoustic error message sounds. An error signal sounds and the two-tone LED keeps flashing.
The error signal can be heard each time you press the key again.
The visual error indication stays active until the error is corrected.
Causes
Display Error
signal
Solution
a- and P-conductor: switched or short circuit
between a- and P-conductor
LED
blinks
orange
switch the a and P conductor or resolve the short
circuit; module will return to standby
a-wire: not connected or without power supply
check a-wire connection or power supply, module will
return to standby
key is locked
(pressed for longer than 15 sec.)
release key,
module will return to standby
9. CONFIGURATION
9.1. Factory settings
Operating mode
code lock
ExtU address for door opening function
0
Send light switch protocol (
-key)
active
Audio signal of
push on the key (confirmation tone)
active
Always first switch on programming mode on power supply and control unit
active
Programming lock
OFF
Master code
serial number of the code lock module
Relay switch time
approx. 3 sec.
Switch relay upon receipt of the door opening protocol
active
Central mode
OFF
1
st
access code (on memory location number 1)
111