51
EN
10-362
Return to standby, terminate speech connection
Display selected goal (name or flat number)
Terminate and confirm entry
Select previous name (row) from name list
Select next name (row) from name list
Request additional information following a door call (voice channel assigned, serial numbers 1 and 2 confirmed)
4.4.2.
Legend actions
Internal unit(s) is (are) called
Operational malfunction (see p. 61)
Internal unit could not be called (ringtone is switched off; internal
unit 1 and/or 2)
Error
a
)
Speech connection; voice channel not assigned
Temperature sensor not found (check serial number, check
temperature sensor)
Speech connection terminated; voice channel not assigned
Confirmation internal unit with serial number 1 ok
Entry of code number
Confirmation internal unit with serial number 2 ok
Code number known, DO is activated
Confirmation serial number 1 not ok (analogue SN 2)
Code number unknown, DO is not activated
a) in combination with the following symbols:
The serial number is unknown or there is no dataset.
An unknown internal unit has not established a speech connection.
No code number entered before the
is pressed or the code number is unknown.
The called internal unit is unknown.
4.5. Technical data
Power supply voltage
+24 V ± 8 % (power supply and control device)
Input current in standby
I(a) = 0.11 mA, I(P) = 7.8 mA
Maximum input current
I(Pmax) = 86 mA
Allowable ambient temperature
-25 ... +55°C
Housing
Anodized aluminium
Display
Plastic
Keys
Plastic with insert in anodized aluminium
Dimensions (in mm)
H 105 x W 105 x D 22
Weight
270 g
3-wire technology required