Note:+50%F.S. is set prior to delivery.
An example of setting 6MPa for switch output 1(SW1 LED is flashing)with 104R.
To set switch output 1 the SW1 LED should be flashing. (To set switch output 2 the SW2 LED should be flashing.)
Note:20counts is set prior to delivery.
An example of setting a hysteresis value of 0.8MPa with the 104R(MPa).
To set hysteresis the“−”LED should be flashing.
To set Digital Filter all LED should be not flashing. An example of setting 2.5s response time by Digital Filter.
Note:“F-0”is set prior to delivery.
+/−
SW1
SW2
+/−
SW1
SW2
M P a
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
H
M P a
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
H
M P a
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
H
M P a
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
H
The LED of an item flashes
when selected using the button.
Hysteresis setting
Switch output 2
setting
Switch output 1
setting
F-0:Response Time=5ms
F-1:Response Time=25ms
F-2:Response Time=250ms
F-3:Response Time=2.5s
Press the and buttons
simultaneously to enter the
Pressure Settings Mode.
(The SW1 LED flashes.)
Press the button to select
between switch output 1 setting
(SW1), switch output 2 setting
(SW2), or the hysteresis setting.
Set the value using the
and buttons.
Press the button for more
than one second to return to
the Operations Mode.
Digital filter setting
Press the and buttons.
Press the button until
all LED do not flashe.
Set the value to “F-3”
using the and
buttons.
Press the button for
more than one second to
return to the Operations
Mode.
Press the button until
the SW1 LED flashes.
Set the value to “6.00”
using the and
buttons.
Press the and buttons.
Press the button until
the −LED flashes.
Set the value to “0.80”
using the and
buttons.
Press the button for
more than one second to
return to the Operations
Mode.
Press the button for
more than one second to
return to the Operations
Mode.
Press the and buttons
6
Switch Output Setting
Hysteresis setting
Digital Filter setting
Pressure Settings Mode