■Window Comparator Mode

 (An example of setting the value“7”for the mode shown in the diagram.)

The switch output setting is determined by the value of the first digit : the red SW2 LED should be 

flashing during the setting.

Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.

Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the

     maximum value corresponds to Setting 2.

Set the value of the first 

digit to“7”using the   

and   buttons.

Press the   button until 

the SW2 LED under the 

first digit flashes.

In the operations mode, 

press the   and   buttons 

simultaneously to enter the 

Initial Settings Mode.

ON

ON

OFF

OFF

SW1

SW2

Setting

value 1

Setting

value 2

Hysteresis

Hysteresis

Low

High

There are four operation modes. These are shown in the diagrams below.

Value selected

Output

Mode

Operation

1
2
3
4
5
6
7
8

SW1 output

Separate

H


L


A


B


H

L

A

B

Window comparator

Note 1

Setting 1

Note 2

Minimum: Setting 1

Maximum: Setting  2

Minimum: Setting 1

Maximum: Setting  2

Note 1

Setting 2

Note 2

Separate Window comparator

SW2 output

Separate Mode

Window Comparator Mode

(H operation)

OFF

ON

-Pr

Pr

H

H

P1:SW1

P2:SW2

ON

OFF

-Pr

Pr

H

H

P1:SW1

P2:SW2

(L operation)

(A operation)

OFF

ON

ON

-Pr

Pr

H

H

P1

P2

P1

P2

(B operation)

OFF

OFF

ON

-Pr

Pr

H

H

P1≦P2 or P1≧P2

P1≦P2−2H

Press the   button for more 

than one second to return to 

the Operations Mode.

M P a

+/−

SW1

SW2

C O PA L     E L E C T R O N I C S

H

M P a

+/−

SW1

SW2

C O PA L     E L E C T R O N I C S

H

M P a

+/−

SW1

SW2

C O PA L     E L E C T R O N I C S

H

M P a

+/−

SW1

SW2

C O PA L     E L E C T R O N I C S

H

5

Switch Output Setting

Содержание PG-35H 104R

Страница 1: ...ater Such as oil solvent and etc and outdoor Do not use pointed objects such as pens to press the setting buttons on the display panel as this may push holes in the setting buttons and damage them Do...

Страница 2: ...o outputs NPN PNP Transistor open collector Switch rating 30VDC100mA maximum Residual voltage 1 2V maximum NPN 2 2V maximum PNP at 100mA Display Operation display Operating conditions Thermal error Fi...

Страница 3: ...itial Settings Mode Setting1 Setting2 Hysteresis 0 300 counts Digital Filter F 0 F 3 Press the and buttons simultaneously Press the button more than one second Press the button more than one second Pr...

Страница 4: ...9 A b 1 0 99 9 1 0 99 9 0 01 1 45 0 10 9 99 1 357 1 350 0 01 5 07 0 1 35 0 0 0102 0 01 145 0 001 Value selected Pressure range Pr Pr Muitiplier factor 104R 354R Set the value of the third digit to 2...

Страница 5: ...F OFF SW1 SW2 Setting value 1 Setting value 2 Hysteresis Hysteresis Low High There are four operation modes These are shown in the diagrams below Value selected Output Mode Operation 1 2 3 4 5 6 7 8 S...

Страница 6: ...25ms F 2 Response Time 250ms F 3 Response Time 2 5s Press the and buttons simultaneously to enter the Pressure Settings Mode The SW1 LED ashes Press the button to select between switch output 1 setti...

Страница 7: ...he applied pressure to the atmospheric pressure and try zero point adjustment again Turn o the power and verify the load connected switch output 1 and 2 E 1 E 2 999Flashing Pressure values exceed the...

Страница 8: ...nd Non Display Temporary Mode will be set After 10 seconds display will go o To disable Non Display Temporary Mode press key for more than 4 seconds will be displayed and Non Display Temporary Mode wi...

Страница 9: ...ng part R2 type 9 Outline Dimensions Unit mm 31 4 COPAL ELECTRONICS 73 2 kPa R1 4 Fe Ni COPAL ELECTRONICS 31 4 kPa 79 2 G3 8 SUS316L 16 10 5 37 Five core shielded cable L 2000 100 Depth5 16 32 Five co...

Страница 10: ...f gauge sides Description Appllcable model Panel holder cover panel holder PG 30 35 PG 35H Holder cover set Main body Panel holder Panel holder cover 24 7 5 7 4 5 40 42 6 COPAL ELECTRONICS kPa 10 Brac...

Отзывы: