A2.2 - Underspeed
Factory setting: 48 Hz for 50 Hz
58 Hz for 60 Hz
1
2
1. Enter the knee-point value between 47.5 and 52.5 Hz (1 step = 0.1 Hz). An error message
appears when the value displayed is outside the permitted range. The extended range is
accessible in expert mode.
2. Enter the gradient value between 1.0 and 3.0 U/F (1 step = 0.1 U/F). Factory setting: 1/U/F.