14
4.3.2 PHA mode (INT)
When the rotation (motion) cycle of a measured object matches with the strobe flash cycle,
the measured object appears to stand still. Use the PHA mode in order to adjust the stop angle (position).
The phase can be changed by 1° using dial within the range between 1° and 359° in the PHA mode.
Press “UNIT” to switch to PHA mode (ms).
(The phase can be changed by 0.01 [ms] within the range between 0.00 and 999.99 [ms] and by 0.1 [ms] within the range
between 1000.0 and 1994.4 [ms].)
A time longer than the light emission cycle cannot be set. (PHA mode ms)
Press “MODE” in PHA mode to switch to FPM mode.
Operation
Display
Increase / decrease
Delay angle / time
Each press of “UNIT”
switches DEG to ms
Press “MODE” to switch
to FPM mode
Decrease delay angle
Increase delay angle
PHA mode (ms)
CCW
CW
CCW
CW
PHA mode
FPM mode
PHA mode (DEG)
Decrease delay time
Increase delay time