25
4.6 Saving function
This unit can save the setting values in two ways.
・
Power OFF save
:
While using the unit while on INT and EXT, turn the power OFF to save the setting value to that
which it was before turning the power OFF.
When the power is turned ON again, operation starts from the previous setting value.
・
Memory save
:
The setting values on the screen can be saved as the SELECT number.
Since the SELECT number have five memories, the setting can be saved as five patterns.
4.6.1 Saving the setting values
The setting values are saved as the following figure.
○
:
save
×
:
cannot save
Memory save
Power OFF save
INT
EXT
Power OFF during
INT
Power OFF during
EXT
Emission setting(INT / EXT)
○
○
○
○
Mode setting(FPM / PHA)
○
○
○
○
INT
The emission count(FPM)
○
×
○
×
Delay angle(PHA)
○
×
○
×
Delay time(PHA)
○
×
○
×
EXT
Delay angle(PHA)
×
○
×
○*1
Delay time(PHA)
×
○
×
○*2
*1
When you press “ZERO” in Delay angle mode, the value (delay angle) on the display is different from the actual value.
In that case, the value on the display will be saved.
*2When you turn the power OFF to save, the calculated delay time based on delay angle will be saved.
SELECT number display
Содержание DT-3015P
Страница 36: ...35 5 2Externaldimensions...
Страница 38: ......
Страница 39: ......
Страница 40: ...Address 1 Terada Kohtari Nagaokakyo city Kyoto 617 0833 Japan Phone 81 75 958 3621...