2.2 Charging 

 

Be sure to charge the battery before initial use. 

Before charging, be sure to check that the power is turned OFF.

 

Please check the state of the power switch OFF with the picture in 

“3.1 Main unit” on page 6. 

 

2.2.1 Charging method 

 

Turn the power OFF, and connect the AC adapter's connector to the main unit.

   

Next insert the AC adapter's AC plug into an outlet. The battery lamp lights up, and charging starts.

 

Charging is complete in approximately 2 hours, and then the charging lamp goes off.

 

The battery lamp( B-CHG ) 

State 

Off 

AC adapter not connected, or Charging complete 

Flash 

Charging error (Stop charging) 

Continuous light 

Charging 

*Be sure to use the supplied AC adapter. 

*Use at the ambient temperature 15°C or higher. 

(If the ambient temperature is lower than 15°C, Charging may not be possible.) 

*If the battery overheats, a charging error may occur. 

 

In this case, let the internal temperature decrease and then reconnect the AC adapter. 

 

 
 
 
 
 

 

Note 1) 

When the power is turned ON during charging, charging is canceled and emission starts. When the unit uses 

the AC adapter as its power source, it is not charged. (Note that emission and charging cannot be performed 

simultaneously.)

 

 

Note 2) 

Though the unit can be charged while battery power still remains, charging will still end when fully charged.   

It is recommended, however, that the unit be charged when the battery has run out ("LLLLLL" is indicated on 

the display) to avoid reducing the battery life itself.

 

 

Note 3) 

If the unit is charged immediately after a long emission time at a high ambient temperature,the temperature 

detection circuit will turn on, and the charging lamp may not light up. In that case, disconnect the AC adapter, 

and let the unit cool. When the product temperature has decreased, connect the AC adapter again and start 

charging. 

Note 4) 

Using in a high temperature environment may shorten the battery life.

 

 
 
 
 
 
 
 
 
 
 
 
 

Remove the connector cover, 
and connect the AC adapter 

Never charge the unit under the following conditions.

 

Adapter of   
another device 

 

 

Using another AC adapter than supplied 

Charging near flammable materials

 

Oil 

Содержание DT-3015P

Страница 1: ...STROBOSCOPE Read this manual thoroughly before use Beforeuse pleasecarefullyreadthesesafetyprecautions aswellasinstructions andfollow them forproperoperation www nidec com jp nidec shimpo INSTRUCTION...

Страница 2: ...ht source Mayresultineyeinjury Do not apply strongimpact to the unit or drop it Failuretofollowthiscouldresult inabnormal operation Avoidthefollowings Water directsunlight condensation dust dirt salt...

Страница 3: ...sion 12 4 3 1FPMmodesetting INT 12 4 3 2PHAmode INT 14 4 4Externalsynchronousemission 15 4 4 1FPMmodesetting EXT 16 4 4 2PHAmodesetting EXT 17 4 5Functionmode 18 4 5 1Thesettingitems 18 4 5 2Instructi...

Страница 4: ...ect frequency when such a still image appears Also a stroboscope can be used to make images of rotating or moving objects stand still or that slightlymoveinordertoobservetheirappearancein slow motion...

Страница 5: ...e 1 When the power is turned ON during charging charging is canceled and emission starts When the unit uses the AC adapter as its power source it is not charged Note that emission and charging cannot...

Страница 6: ...battery decreasesfurther the number display indicates only LLLLLL which provides the emission stop status Press the power switch and shut off the power immediately In either case charge the unit accor...

Страница 7: ...h PowerCable OperationPanel PowerOFF PowerON Thisfigureshowswhenthepowerisoff Please putontheRubbercover one of includedaccessories beforeuse Fit the groove inside the rubber cover with the outer plas...

Страница 8: ...sandholdthisto savethecurrentdisplayandmode settings SIG Select Internal External Parametermode Internal oscillationemission referredtoas INT Flashbyinternal signal External synchronousemission referr...

Страница 9: ...erical display StandardOperation indicatesflashrate PHAMode AngleandTimearedisplayed FunctionMode Each settingvalueisindicated Batterylamp Lightsup whilecharging andgoesoff whenchargingiscomplete Flas...

Страница 10: ...ation Display When thepowerisON Pressthepowerswitch WhenthepoweristurnedON thefollowingindicationmaybedisplayed Thefollowingindicationisanerrormessage whenthereadingpreviouslyused settingvaluefails Pr...

Страница 11: ...dial toreturntothepreviousdisplay 4 1 3HeatLamp Indicator When the ambient temperature of the Xenon lamp rises above a certain level the Heat Lamp Indicator will flash If the temperature risesmore the...

Страница 12: ...ressof SIG switches INT and EXT Power OFF OFF Displaysthemodel PowerON FPMmode INT PHAmode PHAmode Savingfunction Readthesavedvalue SELECTnumber EXT Pressandhold Confirmsaving Returntotheprevious disp...

Страница 13: ...nd Onecycleis360 DisplayofINT 4 3 1FPMmodesetting INT Theemissioncount frequency canbe set inFPMmode TurnthedialinaCW directiontoincreasetheemissioncount andinaCCW directiontodecreaseit Turnthedialfas...

Страница 14: ...ssion count Press 2 to halve the current set the emission count Press MODE to switch to PHAmode FPMmode PHAmode If itisoverthan theflash range nothing will change on the display If itislowerthan thefl...

Страница 15: ...tchtoPHAmode ms The phasecanbechanged by0 01 ms withintherangebetween0 00and999 99 ms and by0 1 ms withintherange between1000 0and1994 4 ms Atimelongerthanthelightemissioncyclecannotbeset PHAmodems Pr...

Страница 16: ...ificationsrange thefollowinglettersareindicated Withoutthedelayangle timesetting Measurablerange27to3300 fpm Withthedelayangle setting Measurablerange27to3300 fpm Withthedelaytimesetting Measurableran...

Страница 17: ...16 4 4 1FPMmodesetting EXT Operation Display Press MODE to switch to PHAmode Press SIG to switch to INT EXTFPMmode INTFPMmode PHAmode Displayinthepreviousunit DEGorms...

Страница 18: ...mode DEG andPHAmode ms The phase can be changed by 0 01 ms within the range between 0 00 and 999 99 ms by 0 1 ms within the range between 1000 0and2216 0 ms Atimelongerthanthelightemissioncyclecannotb...

Страница 19: ...point F2 Triggeredgesetting forEXT Flashintherisingedge Flashinthefallingedge F3 Auto emission stop time setting Emission is performed continuously Stop emission automatically when no operation is pe...

Страница 20: ...mode1 youcansetweathertoadddecimalpoint NotreflectedonEXT Operation Display Change thesetting value Go to function mode2 TurnthepowerON whilepressing MODE Displays Func fortwoseconds Andmovetofunction...

Страница 21: ...ue Go to function mode3 Thissettingchangesthetimingof emissionasshowninthefollowingfigure Indicatesalternately Gotofunctionmode3 Previoussettingvalue Thedefaultsettingis L H CCW L H Risingedge CW H L...

Страница 22: ...nged Operation Display Change thesettingvalue Go to function mode4 Indicatesalternately Previoussettingvale Thedefaultsettingis 0 CCW CW Turnthedialanditwillstop indicatingalternately CW 1 CCW 1 Theti...

Страница 23: ...ettingvalue Go to function mode5 Indicatesalternately Gotofunctionmode5 Previoussettingvale Thedefaultsettingis OFF CCW CW CCW OFF Voltagepulseinput Pulldowntheexternalinputcircuit CW On Opencollector...

Страница 24: ...ration Display Change thesettingvalue Go to function mode6 Indicatesalternately Previoussettingvale Thedefaultsettingis 3000 CCW CW Turnthedialanditwillstop indicatingalternately Increase decreaseby1...

Страница 25: ...nal canbesetto400 secor150 sec Operation Display Change thesettingvalue Savethechanges and goto the homescreen Indicatesalternately Previoussettingvale Thedefaultsettingis 400 Gotothehomescreen CCW CW...

Страница 26: ...es the settingcanbesavedasfivepatterns 4 6 1Saving thesettingvalues The settingvaluesare savedasthefollowingfigure save cannot save Memory save Power OFF save INT EXT Power OFF during INT Power OFF du...

Страница 27: ...d LOAD SAvE andSELECTnumber thedefaultis 1 displayalternatelyevery0 5seconds TurnthedialandchangeSELECTnumbertosave CW 1 CCW 1 When 1 displaysonthescreen turnthedialCWtodisplay 5 When 5 displaysonthes...

Страница 28: ...gthe savingfunction Operation Display Thepowerswitch ON whilepressing 2 and MODE Press 2 and confirminitialization Press 2 and Confirminitialization ThepowerswitchON whilepressing 2 and MODE Displaysf...

Страница 29: ...de Theinitialsetting display Theinitial emission setting EXT Theinitialmode FPM Default SELECTnumber 0 1 INT FPM 1500 PHASE DEG 0 PHASE ms 0 EXT FPM 0 2 PHASE DEG 0 PHASE ms 0 F1 0 0 F2 L H F3 0 F4 OF...

Страница 30: ...andreadthesavingvaluesas thefigureon4 6 1 4 7 2How toreadthememory Operation Display Each pressof LOAD switchesSELECTnumbers OFF 1 2 3 4 5 SELECT 1 OFF SELECT 0 SELECT 2 SELECT 3 SELECT 4 SELECT 5 Se...

Страница 31: ...cGroup Pinnumber Signal name Remarks 1 19V Powerinput 2 19V Powerinput 3 12V Power supply DC12V for sensor 4 OUT External pulseoutput 5 IN External pulseinput 6 GND Power supply DC12V forsensor Extern...

Страница 32: ...ut 4 10 External pulse output Outputspulsestoexternal devicessimultaneously withlightemission Output circuit spec 12 V output Output pulse width about 400 s Output square wave asfollowing figure Input...

Страница 33: ...eflectorandInsert thelampinsertion holderasfarasitwillgo ThenturnitCW twoorthreetimesandpull outstraight withlamp Insertnewlampintothelampinsertionholder with seeigthefigurebelow Andpressittothe socke...

Страница 34: ...hanewbattery Pleasebecarefulthat theharnessfacestheoutside Insert theInsulockattachedtothe batterythroughtheInsulockthrough holeonthetopcover Securetheconnectorcable withtheInsulock sothatthe batteryc...

Страница 35: ...Within the range angle 0 to 359 available to set by1 Within the range time 0 00 to 999 99 ms available to set by 0 01 ms 1000 0to2216 0ms availabletosetby0 1ms Display 6 digit 7 segment red LED Settin...

Страница 36: ...35 5 2Externaldimensions...

Страница 37: ...arging circuit failure Short battery life Emission occurs but does not match the display Nothing is indicated on the display and no emission occurs Factors The Xenon lamp failure The Xenon lamp failur...

Страница 38: ......

Страница 39: ......

Страница 40: ...Address 1 Terada Kohtari Nagaokakyo city Kyoto 617 0833 Japan Phone 81 75 958 3621...