2N – Brake Time
Range:
1 - 30 (seconds)
Default:
1 second
Description:
Sets the duration for DC injection during a braking stop.
<
NOTE
Pr 2N is used in conjunction with Pr 2I. See
Brake
on page 54 for details.
Auto-start and auto-stop
The Digistart D3 can be programmed to start and stop automatically, after a specified delay or at a specified time of
day. Auto-start and auto-stop can be set separately. Auto-start/stop is only available in Remote mode.
WARNING
This function should not be used in conjunction with remote two-wire control.
The soft starter will still accept start and stop commands from the remote inputs or serial communication
network. To disable local or remote control, use Pr 3M.
If auto-start is enabled and the user is in the menu system, auto-start will become active if the menu times
out (if no keypad activity is detected for five minutes).
2O – Auto-Start Type
Options:
Off (default)
The soft starter will not auto-start.
Timer
The soft starter will auto-start after a delay from the next stop,
as specified in Pr 2P.
Clock
The soft starter will auto-start at the time programmed in Pr 2P.
Description:
Selects whether the soft starter will auto-start after a specified delay, or at a time of day.
2P – Auto-Start Time
Range:
00:01 - 24:00 (hours:minutes)
Default:
1 minute
Description:
Sets the time for the soft starter to auto-start, in 24 hour clock format.
2Q – Auto-Stop Type
Options:
Off (default)
The soft starter will not auto-stop.
Timer
The soft starter will auto-stop after a delay from the next start,
as specified in Pr 2R.
Clock
The soft starter will auto-stop at the time programmed in Pr 2R.
Description:
Selects whether the soft starter will auto-stop after a specified delay, or at a time of day.
2R – Auto-Stop Time
Range:
00:01 - 24:00 (hours:minutes)
Default:
1 minute
Description:
Sets the time for the soft starter to auto-stop, in 24 hour clock format.
Содержание D3-0023-B