Digistart D3: User Guide
Issue: G
3.2 Physical Installation
1
3
4
2
08
33
8.
A
1
D3-0023-B ~ D3-0220-B: Allow 100 mm (3.94 inches) between soft starters.
D3-0255-B ~ D3-1000-B: Allow 200 mm (7.88 inches) between soft starters.
D3-0255-N: Allow 100 mm (3.94 inches) between soft starters.
D3-0360-N ~ D3-1600-N: Allow 200 mm (7.88 inches) between soft starters.
2
D3-0023-B ~ D3-0220-B: Allow 50 mm (1.97 inches) between the soft starter and solid surfaces.
D3-0255-B ~ D3-1000-B: Allow 200 mm (7.88 inches) between the soft starter and solid surfaces.
D3-0255-N: Allow 100 mm (3.94 inches) between the soft starter and solid surfaces.
D3-0360-N ~ D3-1600-N: Allow 200 mm (7.88 inches) between the soft starter and solid surfaces.
3
Soft starters may be mounted side by side with no clearance (that is, if mounted without communications
modules).
4
The soft starter may be mounted on its side. Derate the soft starter's rated current by 15%.