7
Technical Data
•
Mains Supply
Mains voltage (L1, L2, L3)
D2-14-xxx ............................................................................. 3 x 200 VAC ~ 440 VAC (+ 10% / - 15%)
D2-16-xxx ............................................................................. 3 x 200 VAC ~ 575 VAC (+ 10% / - 15%)
Mains frequency (at start) .................................................................................................... 45 Hz to 66 Hz
Rated insulation voltage ................................................................................................................ 600 VAC
Form designation ................................................................ Bypassed semiconductor motor starter form 1
•
Control voltage (CSH, CSL, CSR)
D2-1x-xxx-C1 ............................................................................................... 110-240 VAC (+ 10% / - 15%)
or 380-440 VAC (+ 10% / - 15%)
D2-1x-xxx-C2 ............................................................................................ 24 VAC /VDC (+ 10% / - 15%)
Recommended fuse .......................................................... 1 A continuous (10 A max, 0.01 second surge)
Current consumption (during run) ................................................................................................ < 100 mA
Current consumption (inrush) .............................................................................................................. 10 A
•
Inputs
Start (terminal DI1) .............................................................................. Normally open, 150 k
Ω
@ 300 VAC
Stop (terminal DI2) ........................................................................... Normally closed, 150 k
Ω
@ 300 VAC
Motor thermistor ...................................................................................................................... Trip > 3.6 k
Ω
•
Outputs
Main contactor relay (terminals COM2, RLO2) ..................................................................... Normally open
6 A, 30 VDC / 6 A, 250 VAC resistive
Programmable relay (terminals COM1, RLO1) ..................................................................... Normally open
....................................................................................................... 6 A, 30 VDC / 6 A, 250 VAC resistive
•
Environmental
Degree of Protection D2-018 to D2-100 .............................................................................................. IP20
Degree of Protection D2-140 to D2-200 .............................................................................................. IP00
Operating temperature .................................................................................................... - 10 °C to + 60 °C
Storage temperature ..................................................... -25 °C~+ 60 °C (to +70 °C for less than 24 hours)
Humidity ........................................................................................................... 5%~95% Relative Humidity
Pollution degree ............................................................................................................. Pollution Degree 3
Vibration ....................................................................................................... IEC 60068 Test Fc Sinusoidal
4 Hz to 13.2 Hz: ± 1 mm displacement
....................................................................................................................... 13.2 Hz to 200 Hz: ± 0.7 g
•
EMC Emission
Equipment class (EMC) .................................................................................................................. Class B
Conducted radio frequency emission ............................................. 0.15 MHz to 0.5 MHz: < 56-46 dB (µV)
0.5 MHz to 5 MHz: < 46 dB (µV)
5 MHz to 30 MHz: < 50 dB (µV)
Radiated radio frequency emission ................................................... 30 MHz to 230 MHz: < 30 dB (µV/m)
.................................................................................................. 230 MHz to 1000 MHz: < 37 dB (µV/m)
•
EMC Immunity
Electrostatic discharge ............................................................. 4 kV contact discharge, 8 kV air discharge
Radio frequency electromagnetic field .............................................. 0.15 MHz to 1000 MHz: 140 dB (µV)
Rated impulse withstand voltage (Fast transients 5/50 ns) ................ 2 kV line to ground, 1 kV line to line
Voltage dip and short time interruption ................................................... 100 ms (at 40% nominal voltage)
Harmonics and distortion ........................................................... IEC61000-2-4 (Class 3), EN/IEC61800-3
•
Short Circuit
Rated short-circuit current D2-018 to D2-048 .................................................................................... 5 kA
1
Rated short-circuit current D2-060 to D2-200 .................................................................................. 10 kA
1
1
These short circuit ratings are with fuses used as given in the table under
Semiconductor Fuses
on
page 11.
18
Digistart D2: User Guide
Issue: F