49
Issue Number: 2
Figure 5-33 Option 2 for achieving IP55 (NEMA 12) through-panel mounting
50 mm max
(1.97 in max)
5 mm
(0.2 in)
253 mm
(9.96 in)
placed
centrally
along
length
817 mm
(32.17 in)
5 mm
(0.2 in)
817 mm (32.17 in)
Backplate
Enclosure
rear wall
A
B
A
B
1
2
3
4
5
6
M6
M8
6
5
4
3
2
1
Table 5-6 Description of fixings
Table 5-7 Quantity of nylon washers included in the kit boxes
Item
Description
Size
Quantity of M8 (A)
Quantity of M6 (B)
1
Bolt
All
4
4
2
Flat washer
3
Nylon washer (from kitbox)
4
Flat washer
5
Spring washer
6
Nut