10
Unidrive M Modular Installation Guide
Issue Number: 2
2.5 Input line reactor
The INL line reactor must be used in conjunction with the Unidrive M
rectifiers. See section 6.2.2
Input line reactor specifications
for further information.
Figure 2-5 Single input line reactor (INLX0X)/force cooled (INLX0XW)
2.6 Output sharing choke
The OTL output sharing choke must be used on the output of Unidrive M
when more than one module is paralleled together.
Figure 2-6 Single output sharing choke (OTLX0X)
Figure 2-7 Dual output sharing choke (OTLX1X)
For a physical representation of the input line reactors and output
sharing chokes, see section 2.5 and section 2.6
2.7 Model number
The way in which the model numbers for the Unidrive M range are
formed is illustrated below.
Figure 2-8 Rectifier model number
L1
L2
L3
L1A
L2A
L3A
U1
V1
W1
U2
V2
W2
U V W
U1
U2
V1
V2
W1
W2
Drive 1
Drive 2
RECT 10 6 02480 A
Model
Frame size
Voltage 2=200 V
4=400 V
6=690 V
Current rating
Rectifier format
Содержание 09201760D