4
5.
It is highly recommended that a set of safety infra-red beams be used in conjunction with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or barrier.
6.
Over and above the recommendation to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automatic closing feature. It is recommended that a warning light be fitted to any automation system.
7.
The barrier or door warning labels must be installed in a prominent place and/or adjacent to any fixed controls that trigger the
system. These must be in clear line of sight of the barrier or door opening.
8.
The emergency manual release instruction label must be installed on or adjacent to the emergency manual release mechanism.
After installation - It is the responsibility of the installer to ensure the users:
1.
Is proficient in the use of the manual emergency release mechanism.
2.
Is issued with the documentation accompanying this product.
3.
Understands that the barrier or door may not be operated out of clear sight.
4.
Ensures that children are kept clear of the barrier or door area at all times, and that children do not play with the remote
transmitters or any fixed trigger switches linked to the system.
5.
Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger of continuing to use the
automation system in an unsafe condition before a service provider attends to it.
6.
Is proficient in testing the unit’s safety obstruction sensing system.
7.
Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service
provider.
8.
Is aware that a fatigued battery may not be disposed of in the general refuse and must be handed in at a battery merchant for safe
disposal. Before removing the battery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the battery must be removed first.
TECHNICAL SPECIFICATIONS
Technical Data
WIDE M and WIDE L
Primary power supply.
220 – 240Vac @ 50Hz – 60Hz.
Peak power consumption.
240W
Electrical class.
Class 1
.
Motor voltage.
24Vdc.
Motor current.
Current limited to 10A.
Built in battery charger.
Multiple stage auto-calibrating (Peak - 500mA)
Number of operations, within 24hrs of power
failure, on battery reserve.
(Battery health and charge level at time of
power failure dependent)
650 Using 1 x 24V 5Ah battery. (Standard in kit)
950 Using 2 x 24V 3.5Ah batteries.
1300 Using 2 x 24V 5Ah batteries.
Maximum operations per day.
3000
Duty cycle with mains present.
Boom pole open/close speed selection depen-
dent.
98%
Operating speed.
Wide M = 90°/3,5s.
Wide L = 90°/5s.
Torque.
Wide M = 140Nm.
Wide L = 200Nm.
Operating temperature range.
-10 to 50° C (14F to 122F)
Anti-crushing safety sensing.
Yes – Electronic load profiling.
Auxiliary supply output.
12Vdc @ 400mA.
Receiver format.
ET BLU MIX © backward compatible with ET BLUE. (Rolling code)
Receiver frequency.
433.92MHz.
Receiver channels.
4CH (BT, Open only, Aux relay, Holiday lock-out)
Receiver memory capacity.
1023 users.
All users can be allowed control of all channels.
Yes.
Ingress protection.
IP44
Physical dimensions.
See next page.
Technical specifications.