5.

It is highly recommended that a set of safety infra-red beams be used in conjunction with this product. The safety beams must be

installed in such a way that the product is prevented from running when anything is in the path of the door or barrier.

6.

Over and above the recommendation to use safety infra-red beams with this product it is mandatory to install and use a safety

beam set when using the automatic closing feature. It is recommended that a warning light be fitted to any automation system.

7.

The barrier or door warning labels must be installed in a prominent place and/or adjacent to any fixed controls that trigger the

system. These must be in clear line of sight of the barrier or door opening.

8.

The emergency manual release instruction label must be installed on or adjacent to the emergency manual release mechanism.

After installation - It is the responsibility of the installer to ensure the users:

1.

Is proficient in the use of the manual emergency release mechanism.

2.

Is issued with the documentation accompanying this product.

3.

Understands that the barrier or door may not be operated out of clear sight.

4.

Ensures  that  children  are  kept  clear  of  the  barrier  or  door  area  at  all  times,  and  that  children  do  not  play  with  the  remote

transmitters or any fixed trigger switches linked to the system.

5.

Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger of continuing to use the

automation system in an unsafe condition before a service provider attends to it.

6.

Is proficient in testing the unit’s safety obstruction sensing system.

7.

Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service

provider.

8.

Is aware that a fatigued battery may not be disposed of in the general refuse and must be handed in at a battery merchant for safe

disposal. Before removing the battery from the system the household mains must be disconnected. In the case of the motor unit

being removed and scrapped, the battery must be removed first.

TECHNICAL SPECIFICATIONS

Technical Data

WIDE M and WIDE L

Primary power supply.

220 – 240Vac @ 50Hz – 60Hz.

Peak power consumption.

240W

Electrical class.

Class 1

.

Motor voltage.

24Vdc.

Motor current.

Current limited to 10A.

Built in battery charger.

Multiple stage auto-calibrating  (Peak - 500mA)

Number of operations, within 24hrs of power 

failure, on battery reserve.

(Battery health  and charge level at time of 

power failure dependent)

650 Using 1 x 24V 5Ah battery. (Standard in kit)

950 Using 2 x 24V 3.5Ah batteries.

1300 Using 2 x 24V 5Ah batteries.

Maximum operations per day.

3000

Duty cycle with mains present.

Boom pole open/close speed selection depen-

dent.

98%

Operating speed.

Wide M = 90°/3,5s.

Wide L = 90°/5s.

Torque.

Wide M = 140Nm.

Wide L = 200Nm.

Operating temperature range.

-10 to 50° C (14F to 122F)

Anti-crushing safety sensing.

Yes – Electronic load profiling.

Auxiliary supply output.

12Vdc @ 400mA.

Receiver format.

ET BLU MIX © backward compatible with ET BLUE. (Rolling code)

Receiver frequency.

433.92MHz.

Receiver channels.

4CH (BT, Open only, Aux relay, Holiday lock-out)

Receiver memory capacity.

1023 users.

All users can be allowed control of all channels.

Yes.

Ingress protection.

IP44

Physical dimensions.

See next page.

Technical specifications.

Содержание WIDE L

Страница 1: ...ET NICE WIDE INSTRUCTIONS 2018 001 Installer Instructions High Traffic Battery Back up Traffic Barrier www niceforyou com za...

Страница 2: ...ty infra red beams setup Page 20 Selecting a BT operating mode and adjusting the BT auto close time Page 22 Receiver programming and setup Page 29 Advance programming options and their definitions Ope...

Страница 3: ...chanical ends of travel stoppers 5 Ensure all fixed mounting points such as the wall above the door in a garage door system or the posts in a swing barrier system are sound and strong enough to allow...

Страница 4: ...Is proficient in testing the unit s safety obstruction sensing system 7 Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service pro...

Страница 5: ...reflective strips 69x92x5150mm Galvanised steel exten tion coupling joint Red rubber impact pro tection strips 1m lengths Wide M 4m 1 pc 8 lengths Wide L 5m 1 pc 10 lengths Wide L 6m 2 pcs 1 pc 12 len...

Страница 6: ...er 15 15 Operation regularly interrupted by the Emergency Stop circuit trigger 15 15 Speed set to above 50 15 15 Safety overload force level set to above 50 10 10 0 100 000 200 000 300 000 cicli di ma...

Страница 7: ...as per manufacturers cabling requirements 1 Courtesy lights Twin earth 1 0mm back to control card and isolator switch 5 Infra red safety beam RX 3 core 0 5mm stranded back to barrier housing 2 Interco...

Страница 8: ...uits Ref Cable requirements on previous page Fasten the 4 J bolt anchors onto the base plate with one nut above and one nut below the base plate NB the nut below the base plate must be threaded all th...

Страница 9: ...the concrete do the following Position the cabinet in the required positions e Mark out the 4 mounting points f Remove the cabinet and drill the correct size holes for your expansion anchors Not supp...

Страница 10: ...n requires a right hand configuration complete the following 3 steps Factory default LH Closing Top view Right hand closing Top view Left hand closing Opening for boom pole at top Opening for boom pol...

Страница 11: ...k the gearbox in this position A Unlock the gearbox B Move the boom pole to 45 o C Leave the boom pole to rest on the spring tension If the boom poles remains steady without rising or falling move on...

Страница 12: ...12 Adjusting the end stops...

Страница 13: ...ing the AC voltage The ACDC power supply requires 220Vac at the operator This 220Vac must be circuited through a weatherproof all pole isolator switch This isolator switch must be installed within 1 5...

Страница 14: ...el 12Vdc 15A Motor fuse 2A Auxiliary relay fuse BLU Com N C N O 100 Safety beam RX Com N C N O N O N O Loop detector Non polarity sensi ve termina on for 2 wire Bluebus devices For example safety beam...

Страница 15: ...dby Test BT mode when in standby or exit all the way back to standby without saving when in programming Enter programming advance to next level of option on display save value on display Control card...

Страница 16: ...play Display confirms the selection is saved Type Setting Wide L saved Scroll or to select the matching boom pole length Display asks you to select the required boom pole length Set Boom Length 1 2M P...

Страница 17: ...to programming menu options list Overload Setting change x2 x1 x1 Scroll left or right to next program option OR Selected mode Standby EXIT back to standby status x2 Safety infra red beams setup Beam...

Страница 18: ...x Scroll or to the required BT mode option Display changes respectively BT Mode Setting Simplex BT Mode Setting Simplex Auto BT Mode Setting Complex With required setting displayed press and release I...

Страница 19: ...Receiver Setup Quick learn With Quick learn on the display press and release Display prompts you to select a function Select function BT Full opening Scroll or to the required receiver function chann...

Страница 20: ...ess and hold any button on the remote transmitter All four buttons must be set to the same format for this to work in the same way as this example While still transmitting with the remote button press...

Страница 21: ...display press and release Display prompts you to select an available user address Select address 1 used Scroll or to select an available user address Display changes respectively Select address 2 Wit...

Страница 22: ...he display press and release Display shows first erase option Erase Remotes Select Address With Select Address on the display press and release Processor scans the memory and then displays the first a...

Страница 23: ...ss Scroll or to select the Erase ALL memory option Display scrolls through options Erase Remotes Erase ALL memory With Erase ALL memory on the display press and release Display then prompts you to pre...

Страница 24: ...nd release Display prompts you to press and release a remote button Diagnose Remotes Press Remote After prompt Display shows a signal strength graph and waits for a remote transmission Signal Not reco...

Страница 25: ...display press and release Display shows receiver setup options Receiver Setup Quick learn Scroll or to select the Receiver info option Display changes respectively Receiver Setup Receiver info With R...

Страница 26: ...he text and the background of the LCD display Adv Beam Setup In the case of a safety beam circuit being installed without an end of line resistor it is still possible to meet the stringent CE safety s...