SETTINGS OF THE AUTOMATIC FUNCTIONS
Automatic closing
Automatic closing is set on the S2 selector.
The closing times can be set on a value between 0 and 240 seconds.
Special function:
If there is a photoelectric barrier, the time is reduced by 5 seconds
after passage.
Time setting
0
Automatic closing disabled
1
5
seconds
2
10
seconds
3
20
seconds
4
30
seconds
5
45
seconds
6
60
seconds
7
90
seconds
8
120
seconds
9
240
seconds
5
4 6
3
7
2
8
1
90
s2 rotary
switch
Automatic adaptation to the ground
DIP 2 = ON
This function can be used if there is an SBA
sensor.
Advance notice traffic lights
DIP 3 = ON
With this function the red traffic lights
(terminals 1+2) begin to flash 3 seconds
before closing of the door.
Meaning of display messages
Upper segment:
flashing > upper final position setting in progress
ON > upper final position setting completed
Lower segment:
flashing > lower final position setting in progress
ON> lower final position setting completed
movement UP,
movement
DOWN,
upper final position,
preliminary limit switch
,
lower final
position.
Error 3
sensitive edge tripped, for example
In normal operating conditions, the
status of the door and/or the number
of the error present are shown on the
display.
Operation functions
In normal operating conditions, the
status of the door and/or the number
of the error present are shown on the
display. In this case position all DIP
switches on OFF!
Fault display (represented with flashing):
1
Safety circuit
2
Lower sensitive edge fault
3
Lower sensitive edge tripped
4
Lower final position not reached
(time limit)
5
Upper final position not reached
(time limit)
6
Incorrect direction of rotation of motor
7
Power during lifting deactivation
8
Door in the safety limit switch sector
9
The door is not in one of the final
positions. Correction of the final position
is impossible
0
Digital limit switch error
DIP switch functions:
DIP1 “ON“ and 2, 3, 4 “OFF“
Setting of the final positions
DIP1, 2, 4 “ON“ and 3 “OFF“
Precision setting of the final position (upward
movement)
DIP1, 3, 4 “ON“ and 2 “OFF“
Precision setting of the final position
(downward movement)
WARNING:
It is possible to lengthen the duration of the waiting time of a factor
by choice (with selector in position 6 to 9) using the K5 module. The
parameter to be used is P28.
Reversed movement function
DIP 4 = ON
The door blocks and reverses its direction for
about 50 cm if the sensitive edge is enabled
during the downward movement.
DIP 4 = OFF
The door blocks and reaches the upper final
position if the sensitive edge is enabled during
the downward movement.
Содержание UST1K
Страница 2: ......
Страница 12: ...10 Italiano IT CAVO DI COLLEGAMENTO PER MOTORIDUTTORI DOTATI DI FINECORSA ELETTRONICO CON SCHERMATURA...
Страница 13: ...IT Italiano 11 CAVO DI COLLEGAMENTO PER MOTORIDUTTORI DOTATI DI FINECORSA ELETTRONICO SENZA SCHERMATURA...
Страница 14: ...12 Italiano IT CAVO DI COLLEGAMENTO PER MOTORIDUTTORI DOTATI DI FINECORSA MECCANICO CON SCHERMATURA...
Страница 30: ...10 English EN CONNECTION CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITH SCREENING...
Страница 31: ...EN English 11 CONNECTION CABLE FOR GEARMOTORS EQUIPPED WITH ELECTRONIC LIMIT SWITCH WITHOUT SCREENING...
Страница 32: ...12 English EN CONNECTION CABLE FOR GEARMOTORS EQUIPPED WITH MECHANICAL LIMIT SWITCH WITH SCREENING...
Страница 84: ...10 Deutsch DE ANSCHLUSSKABEL F R ANTRIEBE MIT MECH ENDSCHALTER ABGESCHIRMT L nge L...
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...IS0141A00MM_13 07 2013 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...