2
– English
EN
✔
Response with sunshine (intermediate position, Venetian
position or bottom limit).
✔
Response without sunshine (intermediate position, Vene-
tian position, top limit or no movement).
✔
In case of wind, the Venetian blind may receive transmit-
ter commands.
✔
The automatic response to climate sensor signals can
be disabled with the AUTO-ON / AUTO-OFF control of
the ERA P transmitter.
•
MEMORY
✔
Lock memory: this setting prevents further transmitters
from being memorized.
•
DELETIONS
✔
Delete all: restores the TT1VR’s factory settings.
✔
Delete transmitters.
✔
Delete a single transmitter.
✔
Delete positions.
✔
Delete with NON-memorized transmitter.
•
SLIDER
✔
Possibility of using the slider:
- with Venetian blind mode active, the slider allows for
performing tilting (in this mode the Venetian blind moves
in jerks);
- with mechanical motor mode active, if the slider is
pressed in the 0% point it brings the blind/shutter to the
Low limit switch; if pushed in the 100% point, it brings
the blind/shutter to the High limit switch; if, instead, it
is pressed in the 10, 20, 30, 40, 50, 60, 70, 80, 90%
points, it brings the blind/shutter to the corresponding
partial levels.
4
PROGRAMMING
TT1VR programming, must be done ONLY with “ERA P”
transmitters:
the PRG and ESC keys are required
.
These keys are positioned on the back of the transmitter
under a cover plate, to prevent unintentional programming.
4.1 - Programming the FIRST transmitter
by acquisition in Mode 1
This programming automatically memorises all the keys:
command n.1 is automatically mapped to key 1, command
2 to key 2, etc. (depending on the number of keys on the
transmitter).
Tables 1 and 2 describe the available commands:
• Commands available with tilting mode ENABLED
(ideal for Venetian blinds)
TABLE 1
COMMAND DESCRIPTION
▲
(brief)
The blind moves to its top limit position
▼
(brief)
The blind moves to its bottom limit position
▲
(2 s)
Venetian blind tilting upwards
▼
(2 s)
Venetian blind tilting downwards
■
Stop
▲
+
▼
The blind moves to the Venetian position
(if set)
▲
+
■
The blind moves to intermediate position
1 (if set)
• Commands available with tilting mode DISABLED
(ideal for shutters and awnings)
TABLE 2
COMMAND DESCRIPTION
▲
The shutter/awning moves to its top limit
position
▼
The shutter/awning moves to its bottom
limit position
■
Stop
▲
+
▼
The shutter/awning moves to intermedi-
ate position 1 (if set)
▲
+
■
The shutter/awning moves to intermedi-
ate position 2 (if set)
4.1.1 - Mode 1 programming procedure
01.
ON
➔
2
If no transmit-
ters are memorised,
2 movements are
available
02.
PRG
=
10
sec
PRG
3
4.2 - Programming Venetian Position
Hight limit
switch
Low limit
switch
Venetian
position
4.2.1 - Programming procedure Venetian position
01.
PRG
2
02.
=
3
sec
3
03.
the venetian reach automatically the
bottom limit position
04.
to reach the
venetian
position
05.
to save the position
=
3
sec
3
- 6 movements if the procedure was not successfully
completed
4.3 - Memorising an additional transmit-
ter o climate sensor
4.3.1 - Programming with a transmitter without
PRG key
This programming memorises transmitters which do not
have the PRG and ESC keys as well as older transmitters
(in the description of the programming procedure, “
N
” is
the number of presses for the key to be mapped to the