10
– English
EN
To program the limit position
fitted with
a mechanical system:
01.
Press and hold the
Up
(or
Down
) key to move the shutter to mid-travel.
02.
Press and hold the key
(
Up
or
Down)
until the shutter stops on impact
with the limit position (“
0
” or “
1
”) then release the key.
To program the limit position
without
a mechanical system:
01.
Press and hold the
Up
(or
Down
) key to move the shutter to mid-way.
02.
Press and hold the key
(
Up or Down)
to move the shutter to the required
limit position then release the key.
03.
Press and hold the
Up
and
Down
keys simultaneously for at least 3 sec-
onds and release after the motor has executed a brief movement in the
opposite direction.
04.
At this point activate an
Up
or
Down
manoeuvre (depending on the posi-
tion of the shutter) and immediately afterwards a manoeuvre in the oppo-
site direction to enable the control unit to memorise the two limit positions.
CAUTION!
- Do not interrupt these two manoeuvres and do not dis-
connect the power supply from the automation during movement.
4.
3 –
TOTAL MEMORY DELETION
CAUTION!
– This procedure deletes all data from the control unit memory,
including positions “
0
” and “
1
”.
Note
– If positions “0” and “1” are deleted, the main switch must be pressed
continuously (hold-to-run mode) for the entire time required to complete the
manoeuvre.
01.
Press and hold the
Up
and
Down
keys simultaneously for at least 3 sec-
onds and after the motor has executed a brief movement release one key
only.
02.
Within 3 seconds after the motor has executed the movement, press the
previously released key three times.
03.
Then release the other key.