12
–
English
7
PROGRAMMING
In this manual the programming procedures are explained with the use of icons and their meanings are given in the following glossary:
GLOSSARY
Symbol
Description
Symbol
Description
RADIO led on
wait ...
RADIO led off
observe / check
RADIO led flashing
press and release the RADIO key
OFF
shut off mains power
hold down RADIO key
ON
turn on mains power
release RADIO key
04.
Using the key switch, control key or radio transmitter, test the opening and closing of the gate and make sure that it moves in the in-
tended direction
05.
The test should be carried out a number of times to make sure that the gate moves smoothly, that there are no points of excessive
friction and that there are no defects in the assembly or adjustments
06.
Check the operation of the safety equipment, one by one (photocells, sensitive edges, etc.)
07.
Check the operation of the photocells and any interference with other equipment:
1 - pass a dia. 5 cm length 30 cm cylinder along the optical axis, first close to the TX, then close to the RX
2 - check that the photocells trip in any condition, switching from active to alarm and back
3 - check that tripping the photocell results in the intended response of the control unit: e.g., when tripped during a closing stroke, the
gate changes direction.
08.
If the dangerous situations caused by the movement of the door have been safeguarded by limiting the force impact, the user must
measure the impact force according to the EN 12445 standard.
If the adjustment of the “force” is used to assist the system for the reduction of the impact force, try to find the adjustment that gives
the best results.
6.2 - Commissioning
Commissioning can take place only after all testing phases have been terminated successfully (par. 6.1).
Partial or “makeshift” commissioning is strictly prohibited.
01.
Prepare and store the technical documentation for the automation for at least 10 years. This must include at least: an assembly drawing
of the automation, a wiring diagram, an analysis of hazards and solutions adopted, a manufacturer’s declaration of conformity of all
the devices installed (for ROX use the annexed CE declaration of conformity); a copy of the automation system instruction manual and
maintenance schedule.
02.
Affix a label or plate permanently to the gate, bearing instructions on how to manually release the gearmotor: use the figures included
at the end of the User Manual (tearout insert)
03.
Post a permanent label or sign near the gate containing this
picture (min. height 60 mm):
04.
Using the key switch or radio transmitter, test the opening and closing of the gate and make sure that it moves in the intended direction
05.
Prepare the declaration of conformity of the automation system and deliver it to the owner.
06.
Give the owner the user manual (tearout insert)
07.
Prepare and give the owner the maintenance schedule
08.
The force adjustment is an important safety aspect and must be done with care by an expert technician.
Important!
- Adjust the force
to enable the gate to move as intended; higher forces than this can cause injury to animals and persons or damage to property if the
gate collides with an obstacle.
09.
Before commissioning the gate, inform the owner in writing about the attendant residual risks.