English –
17
Switch 5
Operation
On
Closes 5 seconds after ‘Photo’ if set to ‘Automatic’ or ‘Close after Photo’ if set to
‘Semiautomatic’
Switch 6
Operation
On
Safety “Photo” also when Opening
Switch 7
Operation
On
Gradual Start-up
Switch 8
Operation
On
Slow down
Switch 9
Operation
On
Medium braking
Switch 10
Operation
On
Light braking
Switches 1-2:
Manual
operation
The movement is only executed while the control is active (transmitter key held to run).
Semiautomatic
operation
Sending a command executes the entire movement until the operating time expires or the gate trips the
limit switch.
Automatic
operation
After an Open, the system pauses and then automatically Closes the gate.
Always closes
operation
Follows a power failure: if, when power is restored, the control unit determines that the gate is open, it au-
tomatically flashes the flasher for five seconds and then runs a Close cycle.
Switch 3:
Condominium
operation
When a “Step-by-Step” command is sent and the gate starts to Open, it cannot be stopped by any other
“Step-by-Step” or Open command sent by radio until it has completed.
When closing, on the other hand, sending a new Step-by-Step command will stop and reverse the move-
ment.
Switch 4:
When a command is sent, the flasher starts flashing and, after 5 seconds (2 seconds in Manual mode), the movement starts.
Switch 5:
This function, when set in Automatic mode, holds the gate open only for the time required for vehicles or pedestrians to pass through it; when
the Photo device is cleared, the movement stops and a Close movement starts after a 5 second delay.
If the functions is set in Semiautomatic mode, when the photocells are tripped while the gate is closing, automatic Close is activated with the
programmed Pause Time.
Switch 6:
The Photo function is usually active only during Close movements; if micro switch 6 is set to “ON”, tripping the photocell interrupts Open
movements too. On the other hand, in Semiautomatic or Automatic modes, the Open movement starts again as soon as the photocell clears.
Switch 7
This function activates a soft start to gate movements to prevent them moving jerkily.
Switch 8:
Slow down, which reduces the speed to 30% of its nominal value, reduces the impact force of the gate at
the end of a movement.
The gearmotor is factory set with the “slowdown” function active (Switch 8 = ON). The automation will start
slowing down after a time equal to TL/2 (where TL is the set work time). By default the work time is set to
90s (3/4 turn), which means that the slowdown will start 45s after the start of the manoeuvre from the fully
closed or the fully open position.
Depending on the span of the gate, the installer may decide that it is necessary to adjust the work time (TL)
so that the slowdown phase (TL/2) can start roughly 50–70 cm before the intervention of the limit switches
(**). The slow down function not only reduces the speed of the gate but also the torque exerted by the motor
( by 70%).
CAUTION
– In automations which demand a high motor torque, setting this function can stop
the motor.
(**) Note: if this parameter is modified, the resulting change will be visible during the first opening manoeuvre
commanded after the change was made.
30s (15s)
60s (30s)
90s (45s)
120s (60s)
20s (10s)