6

180°

a

180°

b

LIMIT SWITCH

MOTOR

4

ELECTRICAL CONNECTIONS

 CAUTION! - All electrical connections must be carried out with the system disconnected from the mains. Incorrect connections 

can cause damages to the equipment and injuries to people.

Fig. 2 shows the hookup of a typical installation; fig. 7 shows the connections to be made on the control unit.

4.1 - Types of electrical cables

Table 3 - Types of electrical cable (see fig. 2)

Connection

Type of cable

Maximum length

A

POWER

3 x 1.5 mm

2

30 m 

*

B

C

FLASHER WITH AERIAL

1 cable: 2 x 1.5 mm

2

1 shielded RG58 cable

10 m

10 m (< 5 m recommended)

D

PHOTOCELLS

1 cable: 2 x 0.25 mm

2

 (TX)

1 cable: 4 x 0.25 mm

2

 (RX)

30 m

30 m

E - F

KEY SWITCH

1 cable: 2 x 0.5 mm

**

20 m

*

 A power supply cable longer than 30 m may be used provided it has a larger gauge, e.g. 3 x 2.5 mm

2

, and that a safety grounding system 

is provided near the automation unit.

**

 The two 2 x 0.5 mm

2

 cables can be replaced by a single 4 x 0.5 mm

2

 cable.

4.2 - Electrical cable connections: fig. 7

Table 4 - Description of electrical connections

Te r m i -

nals

Function

Description

9 - 10

Stop

- input for devices that lock or stop the current operation; with appropriate precautions, “Normally Closed” or 

“Normally Open” contacts or constant resistance devices can be connected to the input. 

Other information on STOP can be found in paragraph 8.1.1 - STOP input

9 - 11

Photo

- input for safety devices which when tripped reverse the gate's direction of movement: NC (Normally Closed) 

contacts may be used

- for further details, refer to par. 8.1.2 Photocells.

8 - 12

Phototest

Every time a manoeuvre is started, the operation of the photocells is checked; the manoeuvre starts if the test 

is positive. This is possible using a particular type of connections: the transmitters of the “TX” photocells are 

powered separately than the “RX” receivers.

For further details, see paragraph 8.1.2 Photocells.

9 - 13

Step-by-step

input for devices which control movement. NO (Normally Open) contacts can be connected

4 - 5

Flashing light

- flasher output (auto-intermittent)

- when active, the output supplies 230 V

1 - 2

Aerial

- radio receiver aerial input

- aerial integrated into flasher; an external aerial can be used if desired

Содержание ROBO600

Страница 1: ...EN Instructions and warnings for installation For sliding gates Nice ROBO600...

Страница 2: ......

Страница 3: ...TING AND COMMISSIONING 6 1 Testing 14 6 2 Commissioning 14 7 PROGRAMMING GLOSSARY 15 7 1 Adjustable parameters Trimmer TL TP F 16 7 2 Programmable functions 16 7 3 Integrated radio receiver 18 8 DETAI...

Страница 4: ...or allowing contact with liquids of any kind Keep the product away from sources of heat and naked flames Failure to observe the above can damage the product and increase the risk of danger or malfunc...

Страница 5: ...esponding to force N 300 Work cycle cycles hour 20 Notes 1 kg 9 81N example 600N 61 kg 2 APPLICATION LIMITS The effective suitability of ROBO to automate a particular sliding gate depends on the frict...

Страница 6: ...pical installation using Nice accessories a ROBO gearmotor b photocells c posts for photocells d Key switch digital keypad e flasher f rack For the type of electrical cables refer to Table 3 under par...

Страница 7: ...ne below b Bend the two pre cut anchors insert two screws sup plied and lock them with the nuts 03 Now cast the concrete to secure the foundation plate Before the concrete hardens make sure the founda...

Страница 8: ...or is correctly positioned on the foundation plate g Open the gate fully by hand h Rest the first section of rack on the gearmotor s pinion make sure that it corresponds to the start of the gate secti...

Страница 9: ...leaf and the rack k Check that the distance between the pinion and the rack is 1 2 mm If it is not adjust the motor height so that the leaf s weight does not bear on the gearmotor by tightening the a...

Страница 10: ...the gearmotor to the foundation plate 08 Install the OPEN and CLOSE limit switch brackets proceed in the same way for each limit switch OPEN a Slide the gate open by hand stopping it 2 3 cm before th...

Страница 11: ...eck that the casing does not come into contact with the protruding part of the threading If it does eliminate the excess threading 10 a Insert the casing and fasten it with the two screws 1 b Lock the...

Страница 12: ...fig 7 Table 4 Description of electrical connections Te r m i nals Function Description 9 10 Stop input for devices that lock or stop the current operation with appropriate precautions Normally Closed...

Страница 13: ...em to their terminal clamps see fig 7 05 Perform the desired programming chapter 7 7 PROGRAM SWITCH LED RADIO R RADIO SbS IBT4N FLASH 230 V 2 LED FCA LED FCC LED SbS LED PHOTO LED STOP LED 1 1 2 3 4 5...

Страница 14: ...b lock Um zu entr iege ln Par a des bloq uea r Odb loko wan ie Om te deb lokk eren 2 3 1 Per Sblo cca re Pou r d b raye r To unb lock Um zu entr iege ln Par a des bloq uea r Odb loko wan ie Om te deb...

Страница 15: ...d the OK LED must be uninterruptedly on with a green light 5 Release the PROGRAM key within 10 seconds 6 At this point the OK LED flashes green 3 times confirming the recognition is complete 7 If the...

Страница 16: ...the gate moves smoothly that there are no points of excessive friction and that there are no defects in the assembly or adjustments 06 Check the operation of the safety equipment one by one photocell...

Страница 17: ...down the desired key on the radio transmitter to be memorized correct procedure release the transmitter key INCORRECT procedure The control unit has a variety of factory settings which can be reprogra...

Страница 18: ...etween the end of an Open movement and the start of the next Close movement 01 select Automatic and set micro switch 2 to ON 02 set trimmer TP to the desired value 03 to check the time setting run a f...

Страница 19: ...movement stops and a Close movement starts after a 5 second delay If the functions is set in Semiautomatic mode when the photocells are tripped while the gate is closing automatic Close is activated...

Страница 20: ...it does not matter which key is pressed One memory lo cation is occupied for each key N B when memorised in Mode 1 a transmitter can control only one automation Table 8 Transmitter key Command 1 Step...

Страница 21: ...tand close to the control unit 02 NEW transmitter x 3s 03 OLD previously memorised transmitter x 3s 04 NEW transmitter x 3s 05 OLD previously memorised transmitter x 3s RADIO LED not visible at a dist...

Страница 22: ...t until step 04 3 Switch the power back on continue holding the key down ON 4 After 5 seconds the radio led R flashes slowly twice release the key 5s 5 Repeatedly press and release the radio key on th...

Страница 23: ...e devices with 8 2k constant resistance output guarantee category III safety against faults in compliance with the EN 13849 1 standard Note supports 8 2 k or 4 1 k double edge 8 1 2 Photocells To add...

Страница 24: ...ng the IBT4N interface disconnect the control unit from the mains 1 2 10 8 4 Total deletion of the memory When it is necessary to delete the memory completely and go back to the factory set values car...

Страница 25: ...l if an obstacle is really present 4 red flashes 1 sec pause 4 red flashes Activation of the STOP input At the start of the manoeuvre or during the movement the STOP input has been triggered check the...

Страница 26: ...manoeuvre starts and the flasher is off Check that the command is actually received if the command reaches the Step by Step input the OK led flashes twice to indicate that the command has been receive...

Страница 27: ...imilar type of cable Radio receiver Incorporated Operating temperature 20 C 55 C Protection class IP 44 Dimensions mm and weight 330 x 210 x 303 h 11 kg Integrated radio receiver Type 4 channel receiv...

Страница 28: ...U Declaration of conformity and declaration of incorporation as partly completed machinery The full text of the EU declaration of conformity is available at the following internet address https www ni...

Страница 29: ...wan ie Om te deb lokk eren 2 3 1 Per Sblo cca re Pou r d b raye r To unb lock Um zu entr iege ln Par a des bloq uea r Odb loko wan ie Om te deb lokk eren 2 3 1 Per Sblo cca re Pou r d b raye r To unb...

Страница 30: ...28 English NOTE...

Страница 31: ...English 29...

Страница 32: ...IDV0772A01EN_02 07 2021 www niceforyou com Nice S p A Via Callalta 1 31046 Oderzo TV info niceforyou com...

Отзывы: