1) Description of the product:
This gate and door automation unit controls gearmotors with single-
phase alternating current.
It also features a series of functions that can be selected by Dip-
Switch (mini-switches) and adjustments performed by Trimmers.
The control unit features input status Led’s located near such inputs,
while another Led near the microprocessor indicates that the internal
logic works correctly.
To make it easier to recognise the various parts,
fig.1
shows the
main components.
OK
B
A
C
R
D
E
F
G
H
I
L
M
P
S
Z
O
T
U
V
Q
N
W
X
Terminal board for aerial
Function selection Dip-Switch
Step by step button
Working Time TL adjustment trimmer
Pause Time Tp adjustment Trimmer
Input/output control terminal board
Limit switch input connector
Flashing light / courtesy light output terminal board.
Capacitor Connector
Motor power output connector
Power input terminal board
Courtesy light mode selector
Radio slot
Microprocessor
Low voltage rapid fuse (315mA F)
Force adjustment trimmer (F)
OK Led
Transformer
Triac Open
Triac Close
“Common” relay
“Courtesy light” relay
Line fuse (5A F)
A
B
C
D
E
F
G
H
I
L
M
N
O
P
Q
R
S
T
U
V
W
X
Z
1
2.1) Typical system layout
In order to explain certain terms and aspects of an automatic door or gate system, we will now illustrate a typical system layout.
Automatic gate and door systems may only be installed
by qualified fitters in the full respect of the law.
Comply with the warnings shown in the “Warnings for
fitters” file.
!
2) Installation:
2
4
3
PHOTO
2
1
1)
Pair of photocells
2)
Flashing lamp
3)
Keylock selector
4)
Sensitive edge
In particular, please note that:
• All the photocells produced by NICE feature the synchronisation
system which eliminates the problem of interference between
two pairs of photocells (please consult the photocell instructions
for further details).
• The “Photo” pair of photocells have no effect during opening
while they reverse movement during closing.
• The triggering of the sensitive edge connected to the “ALT” input
causes an immediate stop and a short reverse run.
If you need to replace a fuse, be careful to use one of the same type and having identical characteristics:
Dimensions (5x20), rated current (e.g. 5A), blowout characteristics (T=delayed, F=quick), maximum voltage and breaking