“RADIO” Card
The control unit features a connector for plugging in a radio card
SMXI, which activates the “Step-by-Step” and “Stop” input and
allows the control unit to be remote-controlled with a transmitter.
output 1
Step by Step
output 2
STOP
output 3
not used
output 4
not used
8) Accessories
The control unit, being electronic, needs no particular maintenance.
However, periodically make sure (at least once every six months) that
the device adjusting motor force is in perfect working order; adjust
with the trimmer if necessary.
Carry out the whole test phase again to check that the limit switches,
safety devices (photocells, pneumatic edges, etc.) and the flashing
light are in perfect working order.
9) Maintenance
This product is made from various kinds of material, some of which
can be recycled.
Make sure you recycle or dispose of the product in compliance with
current laws and bye-laws.
Some electric components may contain polluting
substances; do not dump them.
!
10) Disposal
This section will help fitters to solve some of the most common
problems that may arise during installation.
No LED is on
• Check whether the control unit is powered (check mains voltage
is present at terminals 1-2 and a voltage of approx. 24 Vac at
terminals 8-9)
• Check the 2 mains fuses have not blown; if none of the Led’s is
on a serious fault has probably occurred and the control unit
should therefore be replaced.
The OK LED flashes regularly but the INPUT Led’s do not
reflect the state of the respective inputs
• Carefully check the connections on input terminals 8÷13.
The manoeuvre does not start
• Check that the Led’s of the “Stop” (FCA + FCC) and “Photo”
safety device are on and that the relative command Led that is
activated (“Step-by-Step”) remains on for the whole duration of
the command.
The gate changes direction during a manoeuvre
An inversion is caused by:
• The photocell triggering (“Photo” during the closing manoeuvre);
in this case, check the connections of the photocells and check
the input Led’s.
11) What to do if ….
Mains power input
: 230 Vac 50/60 Hz
Versions /V1
: 120 Vac 50/60 Hz
Max. current for 24V services
: 200mA (the voltage may vary ± 25%)
Flashing lamp output
: For flashing lamps at mains voltage, maximum power 40 W
Courtesy light output
: Clean contact max. 5A
Operating temperature
: -20 ÷ 70 °C
Working Time
: Adjustable from 2.5 to > 40 s., or from < 40 to > 80 s. with TLM
Pause Time
: Adjustable from 5 to > 80 s
12) Technical specifications