4 - INSTALLATION NOTES 

•  A minimum of two (2) WARNING SIGNS shall be installed, one on each 

side of the gate where easily visible. 

•  Test all features for proper functions before placing the automatic vehicular 

gate opener into service. 

•  Demonstrate the basic functions and safety features of the gate system 

to owners/end users/general contractors, including how to turn off power 

and how to operate the manual release feature. 

•  Leave safety instructions, product literature, installation manual and 

maintenance instructions with end user. 

•  Explain to the owners/users the importance of a service contract that 

includes a routine testing of the entire system including the entrapment 

protection devices, and explain the need for the owners to insure that this 

testing is performed routinely. 

•  Offer the owner/end user a maintenance contract, or contact them 

regularly to offer maintenance. 

•  See instructions on the placement of non contact sensors for each type of 

application.

4.1 - Follow Instructions 

Always follow all instructions included in this manual to ensure safety and the 

longevity of the operator. 

4.2 - Intended usage 

THIS CIRCUIT BOARD IS INTENDED FOR USE WITH VEHICULAR 

SWING AND SLIDE GATES ONLY. 

4.3 - Warnings, cautions and notes 

4.3.1  Gate terms “system, “gate operator”, “gate system”, and “gate 

operator system” for these warnings, cautions, and notes is 

intended to cover the gate controller, gate controller software, the 

gate actuator, and all safety accessories included within a typical 

installation. 

4.3.2  Gate system designers, installers and users must take into 

consideration the inherent hazards associated with each installation, 

since no two installations will be exactly alike. 

4.3.3  Improperly designed, constructed, installed or maintained systems 

can and may introduce hazards which may or may not be readily 

seen or identified by users, bystanders, installers or inspectors 

4.3.4  All pinch points must be guarded or eliminated. 
4.3.5  Only install this gate system opener in appropriate manners in which 

the operation is safe and secure. 

4.3.6  A gate operator exerts a great amount of force in order to move 

the gate system in normal operation, therefore appropriate safety 

sensors, measures, notices and appropriate safety features must be 

incorporated in all installations. 

4.3.7  The gate must be installed correctly and no binding or resistance 

should be present throughout its movement in either direction. 

4.3.8  The gate system must be installed in an area and in such a manner 

in which the gate has sufficient clearance to open, close and 

move without striking or contacting any structures and/or other 

obstructions. 

4.3.9  The gate system is designed for vehicular traffic only, and should 

never, under any situation be used for pedestrian traffic 

4.3.10  Pedestrian prohibited signs, warning signs or other suitable 

measures must be used at minimum, to warn pedestrians to stay 

away from, and to not use this system under any circumstances. 

4.3.11  Pedestrians should be encouraged to use a pedestrian entry/exit 

only. 

4.3.12  Pedestrians should never cross the path of a moving gate. The 

sensors are designed to prevent contact with a vehicle and are 

not necessarily capable of preventing contact with a pedestrian. 

Care should be taken to prevent pedestrian usage under any 

circumstances. 

4.3.13  One or more non-contact sensors must be used in any situation or 

area where entrapment may have the possibility of occurring. 

4.3.14  Gates shall be constructed in accordance with the provisions 

given for the appropriate gate type listed, refer to ASTM F2200 for 

additional gate types. 

4.3.15  Any existing manual gate latches shall be removed or disabled when 

an automatic gate system is installed. Use only mag-locks controlled 

by the system.

3.3 - Gate system safety devices 

Automatic gate operators are designed to move a heavy steel gate. Great 

amounts of force are sometimes used to move these heavy systems. The 

automatic gate system may cause significant damage or injury if the path of 

the gate is obstructed. All sensors, safety devices and warning notices must 

be in place and operable in order for this system to operate properly. It is the 

installer’s responsibility to install this system properly and to ensure its correct 

and safe operation. 

3.4 - Infrared beams and warning signs 

Infrared beams are used to inform the control board that an obstruction is 

present. Safety devices must be installed properly and inspected periodically 

to ensure continued reliability and safety. Safety devices, safety sensors, 

warning signs and notices of moving equipment danger must be installed 

and readily visible by all paths of approach to the gate system. Failure to post 

warnings could result in loss of life, damage or physical injury. 

3.5 - Establish the location 

The installer of this system needs to establish the location of the opener in 

accordance with instructions contained within this manual. A typical layout 

is provided at the end of this manual with a nominal basic drawing. It is the 

installer’s responsibility to ensure that the opener is installed in such a fashion 

so as to prevent binding, pinching or improper articulation of the system 

throughout its actuation cycle. 

3.6 - Read and follow all instructions 
3.7 - Keep children away 

Never let children operate or play with gate controls. Keep the remote control 

away from children. 

3.8 - Test the gate system 

The gate must reverse on contact with a rigid object or stop when an object 

activates the non-contact sensors. After adjusting the force or the limit of 

travel, retest the gate operator. Failure to adjust and retest the gate operator 

properly can increase the risk of injury or death. Test force and correct 

functionality for photo-eyes and other safety devices at least every 6 months. 

ONLY USE the MANUAL RELEASE when the gate is not moving or when the 

unit fails or in case of power outage. 

• Turn the power to the gate controller OFF AND REMOVE BATTERIES 

before using the emergency release. 

3.9 - Keep gates properly maintained 

Have only a qualified service person make repairs. Unqualified service 

technicians are not recommended.

Before installing and/or operating the gate opener, installers and/or users 
should do the following: 
•  Confirm the gate operator being installed is appropriate for the application. 
•  Confirm the gate is designed and built according to current applicable 

published industry standards. 

•  Confirm all appropriate features and accessory devices are being 

incorporated, including both primary and secondary entrapment protection 
devices. 

•  Make sure the gate works freely before installing the operator. 
•  Repair or service worn or damaged gate hardware before installing the 

operator. 

•  Adjust the FORCE device to the minimum force setting that allows reliable 

gate operation. 

•  Install operator inside fence line (DO NOT install operator on public side of 

fence line). 

•  Swinging gates shall not open into public access areas. 
•  Install a proper electrical ground to a gate operator. 
•  Install keypad controls where users cannot touch, or reach through gate 

while operating controls, which is a minimum of 8 feet from the gate. 

•  Install controls where user has full view of gate operation. 
•  Install all warning signs (In accordance with UL 325) on both sides of the 

gate to warn persons in the area of potential hazards associated with the 
automatic vehicular gate operation.

Содержание 73001K

Страница 1: ...Nice Apollo Slide Gate Opener Vehicular Slide Gate Operator Revision 1 0 0 0_2 2014 Model 73001K...

Страница 2: ......

Страница 3: ...INCOMING POWER WIRING 10 11 LIMIT AND MOTOR WIRING 11 12 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 13 SETTING LIMIT SWITCHES 12 14 QUICK RELEASE OPERATION 13 15 LEARNING MODE 14 16 ACCESSORY INPUTS A...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Страница 8: ...tions Power Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections 73001K Control Box Chain Bracket 2 10020715 U Bolts 4 5 16 x 2 40 Roller C...

Страница 9: ...lied 2 U Bolts or by tack welding in place Put the gate in the center of travel of the opening The gate should remain in this position while the chain is attached to the operator DRIVEWAY Direction of...

Страница 10: ...to the solar panel terminal block The positive wire of the panel connects to the left terminal marked Note If the panel is connected backwards a red LED will illuminate below the terminal Battery Con...

Страница 11: ...below Note If the gate moves in the opposite direction from what is expected reverse the actuator wiring from what is shown Red to Pin 1 Black to Pin 3 Motor wiring Connect the motor leads to the 3 p...

Страница 12: ...the button down until the gate reaches the fully intended open position 2 Adjust the Open Limit on the operator until the GREEN light illuminates on the front of the control board as shown above The f...

Страница 13: ...quick release assembly by pulling the handle until the lock pins seperate from the sprocket and turning in either direction a half turn Note If the gate or motor is in a bind the chain could be tight...

Страница 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 16: ...ting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receiver...

Страница 17: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Страница 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 19 2 Magnetic lock connection...

Страница 19: ...ipment and connections Clean equipment and connections 20 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 20 7 Poor mechanical o...

Страница 20: ...op Sensors and Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Loop Safety Loop Safety Loop Exit 4 Min from closed gate 4 Mi...

Страница 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 24 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 27: ...27 1 1 2 2 A A B B COMPANY NICEAPOLLO 7300ETL GENERAL OVERVIEW 18 26 15 19 50 75 75 9 63 1 00 11 63 25 37 20 12 15 25 13 50...

Страница 28: ...SPROCKET 35B25 1 5 LIMIT SPROCKET QUICK RELEASE 25B24 1 6 FLANGE BEARING UCFL202 2 7 DRIVE SPROCKET 40B17 1 8 CHAIN COVER 10030590 1 9 NICE RECEIVER 318NPI 1 10 IDLER SPROCKET 40BB17H 1 11 1050 CIRCU...

Страница 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 30: ...30...

Страница 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Страница 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Отзывы: