background image

21

22 - ACCESSORIES AND SENSORS 

EXTERNAL ENTRAPMENT PROTECTION 

Non-contact and contact sensors must be installed individually or in combination with each other to provide external entrapment protection. 

Care should be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving, and one or more non-

contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. 

A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to 

mechanical damage. 

A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located 

where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. 

DURING INSTALLATION 

•  DISCONNECT POWER at the control panel before making any electric service power connection. 
•  Be aware of all moving parts and avoid close proximity to any pinch points. 
•  Know how to operate the manual release. 
•  Adjust the unit to use the minimum force required to operate the gate smoothly even during mid-travel reversing. 
•  Place controls a minimum of 8 feet away from the gate so that the user can see the gate and operate controls but cannot touch the gate or gate operator 

while operating the controls. 

•  Warning signs must be placed on each side of the gate or in high-visibility areas to alert of automatic gate operations.

Moving Gate can cause

Serious Injury or Death. 

Persons are to keep clear! The gate is able to be moved without prior warning.
Do not allow children to operate gate or play in gate area.
This entrance is for vehicles only. Pedestrians must use separate entrance.

Le portail en mouvement peut causer 

des blessures graves ou la mort. 

Les personnes ne devront pas s’approcher! 
Le portail est capable d'être bougé sans avertissement préalable.
Ne pas laisser les enfants utiliser le portail ou jouer dans le domaine du portail.
Cette entrée est réservée aux véhicules. 
Les piétons devront utiliser une entrée séparée.

Содержание 73001K

Страница 1: ...Nice Apollo Slide Gate Opener Vehicular Slide Gate Operator Revision 1 0 0 0_2 2014 Model 73001K...

Страница 2: ......

Страница 3: ...INCOMING POWER WIRING 10 11 LIMIT AND MOTOR WIRING 11 12 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 13 SETTING LIMIT SWITCHES 12 14 QUICK RELEASE OPERATION 13 15 LEARNING MODE 14 16 ACCESSORY INPUTS A...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Страница 8: ...tions Power Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections 73001K Control Box Chain Bracket 2 10020715 U Bolts 4 5 16 x 2 40 Roller C...

Страница 9: ...lied 2 U Bolts or by tack welding in place Put the gate in the center of travel of the opening The gate should remain in this position while the chain is attached to the operator DRIVEWAY Direction of...

Страница 10: ...to the solar panel terminal block The positive wire of the panel connects to the left terminal marked Note If the panel is connected backwards a red LED will illuminate below the terminal Battery Con...

Страница 11: ...below Note If the gate moves in the opposite direction from what is expected reverse the actuator wiring from what is shown Red to Pin 1 Black to Pin 3 Motor wiring Connect the motor leads to the 3 p...

Страница 12: ...the button down until the gate reaches the fully intended open position 2 Adjust the Open Limit on the operator until the GREEN light illuminates on the front of the control board as shown above The f...

Страница 13: ...quick release assembly by pulling the handle until the lock pins seperate from the sprocket and turning in either direction a half turn Note If the gate or motor is in a bind the chain could be tight...

Страница 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 16: ...ting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receiver...

Страница 17: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Страница 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 19 2 Magnetic lock connection...

Страница 19: ...ipment and connections Clean equipment and connections 20 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 20 7 Poor mechanical o...

Страница 20: ...op Sensors and Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Loop Safety Loop Safety Loop Exit 4 Min from closed gate 4 Mi...

Страница 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 24 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 27: ...27 1 1 2 2 A A B B COMPANY NICEAPOLLO 7300ETL GENERAL OVERVIEW 18 26 15 19 50 75 75 9 63 1 00 11 63 25 37 20 12 15 25 13 50...

Страница 28: ...SPROCKET 35B25 1 5 LIMIT SPROCKET QUICK RELEASE 25B24 1 6 FLANGE BEARING UCFL202 2 7 DRIVE SPROCKET 40B17 1 8 CHAIN COVER 10030590 1 9 NICE RECEIVER 318NPI 1 10 IDLER SPROCKET 40BB17H 1 11 1050 CIRCU...

Страница 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 30: ...30...

Страница 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Страница 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...