background image

29

Nice Group USA Limited Warranty – 2 (TWO) YEARS 

Nice Group USA (“Manufacturer”) warrants this product shall be free from defects in materials and 
workmanship for a period of 2 years from the manufacture date. These warranties are in lieu of all other 
warranties expressed or implied and shall be considered void if the product is damaged due to, but 
not limited to, improper installation, improper use, terrorism or acts of God. The proper operation of 
this product is dependent on your compliance with the instructions regarding installation, operation, 
maintenance, and testing. Failure to comply strictly with those instructions will void this limited warranty in 
its entirety. 

If, during the 2 year time period from the date of manufacture,

 

this product appears to contain a defect 

covered by this limited warranty, 

call the manufacturer service center at 1-800-226-0178 

before 

uninstalling and/or dismantling this product. The technical assistance department at the manufacturer 
will discuss the problems you are experiencing in order to confirm the product defect. You will provide 
the information from the dated proof of purchase receipt to confirm the warranty period or the technician 
will confirm your extended warranty period through your registration information on file. The technician 
will give you the shipping information you need to return your product. Your product must be returned to 
the manufacturer service center in a prepaid and insured manner. Should your product be covered under 
the warranty policy, your product will be repaired, replaced with a factory rebuilt product or replaced with 
a new product (at the manufacturer’s discretion) at no cost to you and sent back to you via standard 
ground freight. 

THIS WARRANTY AND THE OBLIGATIONS AND LIABILITIES OF MANUFACTURER ARE 
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING 
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE.

 Under no circumstances shall the manufacturer be liable for consequential, 

incidental or special damages of any kind whatsoever. The manufacturer’s liability for a breach 
of warranty, breach of contract, negligence or strict liability cannot exceed the cost of the 
warrantied product. No person is authorized to assume for the manufacturer any other liability 
in connection with the sale of this product.

 

31 - WARRANTY

Содержание 72001K

Страница 1: ...Nice Apollo Slide Gate Opener Vehicular Slide Gate Operator Revision 1 0 0 0_2 2014 Model 72001K...

Страница 2: ......

Страница 3: ...MING POWER WIRING 10 11 LIMIT AND MOTOR WIRING 11 12 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 13 SETTING THE LIMIT SWITCHES 12 14 QUICK RELEASE OPERATION 13 15 LEARNING MODE 14 16 ACCESSORY INPUTS A...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Страница 8: ...r Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections 72001K Control Box Chain Bracket 2 10020715 U Bolts 4 5 16 x 3 U Bolts 4 5 16 x 2 40...

Страница 9: ...ning Centerline of gate 6 24 Inside posts 5 Mount operator to posts at desired height using the four supplied 3 U Bolts and tighten into place making sure operator is level 8 CHASSIS MOUNTING 9 CHAIN...

Страница 10: ...backwards a red LED will illuminate below the terminal If solar power is to be used it will be necessary to program control board for STANDBY operation See section 16 for information on STANDBY mode...

Страница 11: ...below Note If the gate moves in the opposite direction from what is expected reverse the actuator wiring from what is shown Red to Pin 3 Black to Pin 1 Motor wiring Connect the motor leads to the 3 p...

Страница 12: ...ard as shown above The fully CLOSED limit switch is now set Note if green LED illuminates reverse orange and white limit wires MOTOR 1 LED RED MOTOR 2 LED RED The limit adjustments are located inside...

Страница 13: ...by pulling the handle until the lock pins seperate from the sprocket and turning in either direction a half turn Note If the gate or motor is in a bind the chain could be tight and cause increased pr...

Страница 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 16: ...ting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receiver...

Страница 17: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Страница 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 19 2 Magnetic lock connection...

Страница 19: ...ty equipment and connections Clean equipment and connections 20 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 20 7 Poor mechan...

Страница 20: ...op Sensors and Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Loop Safety Loop Safety Loop Exit 4 Min from closed gate 4 Mi...

Страница 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 24 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 27: ...27 1 1 2 2 A A B B COMPANY NICEAPOLLO NAME 7200ETL GENERAL OVERVIEW 14 59 31 50 20 00 75 63 3 50 23 25 63 11 28 21 20 4 81 21 50...

Страница 28: ...10037390 1 6 LID 10053890 1 7 NICE RECEIVER 318NPI 1 8 DRIVE SPROCKET 40B17 1 9 FLANGE BEARING UCFL202 2 10 LIMIT SPROCKET QUICK RELEASE 25B24 1 11 IDLER SPROCKET 40BB17H 2 12 FRAME 10003590 1 13 CHA...

Страница 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 30: ...30...

Страница 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Страница 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...