SOLAR ELECTRICITY (ACCESSORY IS REQUIRED)
affect room temperature
solar electricity 4.1.10
affect hot water
affect pool temperature
external energy meter
prioritise domestic electricity
affect room temperature
Setting range: on/off
Factory setting: off
affect hot water
Setting range: on/off
Factory setting: off
affect pool temperature
Setting range: on/off
Factory setting: off
3-phase (EME 10)
Setting range: on/off
Factory setting: off
prioritise domestic electricity (EME 20)
Setting range: on/off
Factory setting: off
Menu
4.1.10
This is where you set which part of your installation (room temperature, hot
water temperature, pool temperature) is to benefit from the solar electricity
surplus.
When the solar panels produce more electricity than VVM 225 requires, the
temperature in the property is adjusted and/or the temperature of the hot water
is increased.
EME
In this menu you can also make settings that are specific for your EME.
For EME 10, you enter if it is connected as 3-phase.
For EME 20, you can select whether you want domestic electricity to be priorit-
ised ahead of room temperature and hot water, provided that VVM 225 is
equipped with an external energy meter.
OP. MODE
Menu
4.2
67
Chapter 3 | VVM 225 – at your service