heating curve
heating curve 1.9.1.1
system
outdoor temp. °C
flow temperature °C
Setting range: 0 – 15
Default value: 9
cooling curve
cooling curve 1.9.1.2
system
outdoor temp. °C
flow temperature °C
Setting range: 0 – 9
Default value: 0
The prescribed heating curve for your house can be viewed in the menu
curve
.
The task of the heating curve is to give an even indoor temperature, regardless
of the outdoor temperature, and thereby energy efficient operation. It is from
this heating curve that the indoor module’s control computer determines the
temperature of the water to the heating system, supply temperature, and
therefore the indoor temperature. Select the heating curve and read off how the
supply temperature changes at different outdoor temperatures here. If there is
access to cooling the same settings can be made for the cooling curve.
35
Chapter 3 | VVM 225 – at your service
NIBE VVM 225
Содержание VVM 225