Increases or decreases in the accommodation temperature can be scheduled
here for up to three time periods per day. If a room sensor is installed and activ-
ated the desired room temperature (°C) is set during the time period. Without
Menu
1.3.1
an activated room sensor the desired change is set (of setting in menu 1.1). One
step is usually enough to change the room temperature by one degree, but in
some cases several steps may be required.
SCHEDULING HEATING
1.3.1
activated
schedule 2
system
schedule 3
schedule 1
all
mon
tues
wed
thur
fri
sat
sun
21:30 - 06:00
20.5°
Time period
Adjusting
Day
Activated
Schedule
System
Conflict
Schedule:
The schedule to be changed is selected here.
Activated:
Scheduling for the selected period is activated here. Set times are
not affected at deactivation.
System:
The climate system that the relevant schedule relates to is selected
here. This alternative is only displayed if there is more than one climate system.
Day:
Select which day or days of the week the scheduling is to apply to here.
To remove the scheduling for a particular day, the time for that day must be reset
by setting the start time to the same as the stop time. If the row "all" is used, all
days in the period are set according to that row.
Time period:
The start and stop time for the selected day for scheduling are se-
lected here.
Adjustment:
How much the heating curve is to be offset in relation to menu 1.1
during scheduling is set here. If a room sensor is installed, the desired room
temperature is set in °C.
Conflict:
If two settings conflict with each other, a red exclamation mark is dis-
NIBE VVM 225
Chapter 3 | VVM 225 – at your service
30